Argo Argoclima Magico Operating Instructions Manual Download Page 4

4

OPERATION

COOLING

Place the air conditioner as near as possible to the window. Fit the flexible tube by
hooking it to the rear of the unit. Extend the flexible tube just enough to reach the
outdoor, passing under the window shutters set ajar.

In case there is a window sill towards the inside of the room, it might be better to
use  the  supplied  outlet  nozzle.  Insert  the  nozzle  into  the  free  end  of  the  flexible
tube.

Open the window and lock one of the shutters. Place the outlet nozzle between the
two shutters, held together with the supplied lace.

Avoid sharp bends or plies of the flexible tube.

In case of porthole utilise make a 140 mm diameter hole in the window pane.

NO!

When the air conditioner is in the dehumidification mode, it doesn

t cool the room.

When  you  use  the  air  conditioner  in  the  dehumidification  mode,  you  don

t  have  to

use  the  flexible  tube.  For  maximum  dehumidification  efficiency  leave  the  rear 
discharge outlet free to discharge directly into the room. 

Remove  the  flexible  tube  by  grasping  it  at  the  attachment  point  on  the  air 
conditioner and twisting it until you release it from the blocking hooks.

DEHUMIDIFICATION (DRY)

HOW TO INSTALL BATTERIES

Remove the lid in the rear part of the remote control unit. 

Insert two AAA alkaline batteries of 1,5 V-DC.
Make sure the batteries point in the direction marked in the
battery compartment.

The  batteries  last  about  six  months.  Depending  on  how
much you use the remote control unit.
Remove  the  batteries  if  you  do  not  use  the  remote  control
unit for more than one month.
Press  the  +,  -,  SET  and  CLEAR  buttons  together  after 
batteries replacement. 
(This  operation  allows  you  to  reset  correctly  all  the 
programs. The remote control unit is to be set up again).
Replace  the  batteries  when    the  remote  control  unit  lamp
fails  to  light,  or  when  the  air  conditioner  does  not  receive
the remote control unit signals.

The  batteries  of  the  remote  control  contain  polluted 
substances  exhausted  batteries  must  be  disposed 
according to the laws in force.

USING THE REMOTE CONTROL UNIT

TEMPERATURE SENSOR SELECTOR

Under  normal  conditions  the  room  temperature  is  detected
and  checked  by  the  temperature  sensor  placed  in  the 
air conditioner.

Press  the  remote  control  I  FEEL  button  to  activate  the  tem-
perature sensor placed in the remote control. This function is
designed to provide a personalised environment by transmit-
ting the temperature control command from the location next
to  you.  Therefore,  in  using  this  function,  the  remote  control
should  always  be  aimed,  without  obstruction,  at  the 
air conditioner.

The  remote  control  unit  sends
the temperature signal to the air
conditioner  regularly  at  two
minute  intervals.  If  the  signal
from  the  remote  control  unit
stops  for  more  than  five 
minutes  due  to  some  troubles,
the  air  conditioner  will  switch
to  the  temperature  sensor
which is built into the unit and controls the room tempera-
ture.  In  these  cases,  the  temperature  around  the  remote
control  unit  may  differ  from  the  temperature 
detected in the air conditioner position.

NOTE

VISORE TELECOMANDO

OPERATION WITH THE REMOTE CONTROL UNIT

When using the remote control unit, always point the unit trans-
mitter head directly at the air conditioner receiver.

TRANSMITTER HEAD

REMOTE CONTROL UNIT

RECEIVER

EG

Summary of Contents for Argoclima Magico

Page 1: ...NSTRUCTIONS ISTRUZIONI D USO NOTICE D UTILISATION BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO INSTRUC ES DE FUNCIONAMENTO 37 4252 008 2 06 2005 Save these instructions Conservate queste istruzioni Conser...

Page 2: ...his equipment at your local community waste collec tion recycling centre In the European Union there are sepa rate collection systems for used elec trical and electronic products Please help us to con...

Page 3: ...fuses etc are of sufficient capacity to handle a start up current of 20 A generally less then 1 second Do not install the air conditioner where it could be wetted by drops of water i e in laundries B...

Page 4: ...han one month Press the SET and CLEAR buttons together after batteries replacement This operation allows you to reset correctly all the programs The remote control unit is to be set up again Replace t...

Page 5: ...gh speed Medium speed Low speed Operation Mode Cooling Fan speed indication High speed Automatic fan speed Medium speed Low speed Dehumidification dry Displayed when data trasmitted Or remote control...

Page 6: ...on will slightly differ from that described in the above tables ADJUSTING THE FAN SPEED AUTOMATIC Simply set the FAN SPEED selector to the position A microcomputer automatically controls the fan speed...

Page 7: ...set for ON and OFF separately for two different time periods and they are effective two days only These timers will be effective on the day of setting and on the day after only At 24 00 on the second...

Page 8: ...rear of the air conditioner Close with the inch the open end of the tube and tilting it towards the container let the condensate water flow At the end of the operations reinsert the discharge tube in...

Page 9: ...is OFF 5 Batteries in remote control unit have run down Remedy 1 Restore power 2 Contact service centre 3 Consult your electrician or dealer 4 Press the button again 5 Replace batteries The use of por...

Page 10: ...t with lukewarm soapy water then rinse in clean cold water and dry it before reinstallation 2 Cleaning of Casing and Grilles To clean the air conditioner wipe it with a clean soft cloth lightly moiste...