![Argo AEI 25 AH Technical & Service Manual Download Page 23](http://html.mh-extra.com/html/argo/aei-25-ah/aei-25-ah_technical-and-service-manual_2967446023.webp)
23
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
AWI 25 AHL
Outdoor Unit
AEI 25 AH
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.17
Power input
kW
0.033
0.21
0.048
Rating conditions:
Indoor air temperature: 27
°
C D.B. / 19
°
C W.B.
Outdoor air temperature: 35
°
C D.B.
Rating conditions:
Indoor air temperature
20
°
C D.B.
Outdoor air temperature
7
°
C D.B. / 6
°
C W.B.
Heating
Cooling
3.48
0.674
3.86
0.755
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.17
Power input
kW
0.035
0.21
0.048
4.43
0.912
4.81
0.995
Indoor Unit
AWI 35 AHL
Outdoor Unit
AEI 35 AH
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.17
Power input
kW
0.035
0.14
0.030
Rating conditions:
Indoor air temperature: 27
°
C D.B. / 19
°
C W.B.
Outdoor air temperature: 35
°
C D.B.
Rating conditions:
Indoor air temperature: 20
°
C D.B.
Outdoor air temperature: 7
°
C D.B. / 6
°
C W.B.
Heating
Cooling
4.90
1.025
5.21
1.090
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.17
Power input
kW
0.035
0.14
0.030
5.17
1.100
5.48
1.165