Argo ADIBS13DC Operating Instructions Manual Download Page 1

EG

I

F

D

E

P

OPERATING INSTRUCTIONS • 

ISTRUZIONI D’USO

NOTICE D’UTILISATION • 

BEDIENUNGSANLEITUNG

INSTRUCCIONES DE USO • 

MANUAL DE INSTRUÇÕES

ΟΔΗΛΙΕΣ XPHΣΕΩΣ

37.4254.071.00    11/2015

Split air conditioner system • 

Condizionatore d’aria split system

Climatiseurs split • 

Split-klimagerät

Acondicionador de aire de consola partida sistema split • 

Aparelho de ar condicionado-Sistema Split

DIAIROUMENES MONADES KLIMASMOU

ADIBS13DC
ADICS13DC

GR

Summary of Contents for ADIBS13DC

Page 1: ...SO MANUAL DE INSTRUÇÕES ΟΔΗΛΙΕΣ XPHΣΕΩΣ 37 4254 071 00 11 2015 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimagerät Acondicionador de aire de consola partida sistema split Aparelho de ar condicionado Sistema Split DIAIROUMENES MONADES KLIMASMOU ADIBS13DC ADICS13DC GR ...

Page 2: ...OUBLESHOOTING 10 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 14 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number ALERT SYMBOLS EG WARNING CAUTION DECLARATION ...

Page 3: ...y WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 5 6 7 8 9 3 10 11 2 1 4 NOTA When the unit receives a signal from the remote controller all the three lamps OPERATION TIMER and STANDBY light up for a moment to indicate the correct signal reception OFF LAMPS FUNTION It is possible to set the air conditioner in order to let the OPERATION TIMER and STANDBY lamps always OFF even during operati...

Page 4: ...the remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the temperature sensor placed in the remote controller I FEEL icon displayed This function is designed to provide a comfortable room temperature by transmitting the temperature control command from the location...

Page 5: ...G THE TIMER IFEEL IFEEL C SENSOR SELECTOR Press this button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically s e l e c t e d b y t h e microcomputer High speed Medium speed Low speed ON OFF BUTTON This button turns the air conditioner ON and OFF FLAP BUTTON NOT AVAILABLE NIGHT ECO BUT...

Page 6: ... SHOW THE ROOM TEMPERATURE AGAIN 3 Press the FAN selector button to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automatically adjusted not only according to the air temperature but also based on the relative humidity according to the humidex index Verify that the unit is connected to the main power and the STANDBY l...

Page 7: ...des the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating mode an error will be signaled for this unit wrong operating mode If the same unit is switched on in automatic mode and the desired temperature is lower than the detected ambient temperature the unit...

Page 8: ...button to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit to operate for one hour at the set conditions regardless of whether the unit is on or off C 4 2 2 3 1 SETTING THE HOLIDAY TIMER The Holiday Timer function allows you to activate the indoor unit eith...

Page 9: ...t has troubles follow the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT THE REMOTE CONTROL UNIT The air conditioner will start in HIGH fan speed The temperature setting is 25 C for cooling mode and 21 C for heating mode NOTE CARE AND CLEANING l Maintenance...

Page 10: ...uble the air conditioner does not run at all Possible cause 1 Power failure 2 Leakage breaker tripped 3 Operation button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2 Contact service centre 3 Press the button again 4 Replace batteries Trouble Poor cooling or heating performance Possible cause 1 Dirty or clogged air filters 2 Heat source or many people in room 3 D...

Page 11: ... and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the indications of the diagnosis for the outdoor unit E2 F O O Malfunctioning of the condensate draina ge system Fan is stopped and flap is closed Condensate drainage pump is acti vated The system restarts...

Page 12: ...eck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h e communication cable is properly connected to every terminal Check the communication fuse on outdoor and indoor unit Check that the outdoor unit has power supply and that it is working Check that a...

Page 13: ...ical wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Check that the fan motor is properly connected to the PCB as shown in the electrical wiring diagram Check that the fan motor is not locked Check that the fan motor is not damaged and if necessary replace...

Page 14: ...r providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dispose of this equipment separately the battery is marked with a crossed out dustbin RE...

Page 15: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com ...