Connect the suction and return hose (DN 6, black color) to the quick fitting couplings (item 9 and item 10) at the adapter
(item 4) (see illustration 4)
Pos. 4
Pos. 9
Pos. 10
Illustration 4:
Adapter with quick fitting couplings
›
Connect the connecting cable to the interface (item 11) of the filter unit (see illustration 5).
Pos. 11
Illustration 5:
View of Filter Unit UMP 045
2.11 On start up check
›
If the filter unit is tight / sealed.
›
If the direction of rotation of the motor matches the direction of rotation arrow on the motor housing. If not, only allow specialized
staff to invert the phases (only with 3-phase motor).
›
De-aeration of the unit: To ventilate the unit automatically, release the black cap at the ventilating valve (see page 9),
but do not unscrew it.
By means of manual de-aeration (red cap), the ventilating valve can be checked. With activation, oil must escape within a short time.
By this check-up you additionally prevent jamming of the float valve.
2.12 If there is an unexpected power failure, it is essential to note these points
›
Switch off the unit or disconnect from the mains supply to prevent the possibility of subsequent damage to the environment and /
or people when the power returns.
→
Possible subsequent damage:
- oil may overflow
- danger of slipping on leaked oil