![Argo-Hytos RPE3-062 S3 Series Operating Instructions Manual Download Page 7](http://html1.mh-extra.com/html/argo-hytos/rpe3-062-s3-series/rpe3-062-s3-series_operating-instructions-manual_2967778007.webp)
Operating_Instructions_RPE3-062x/xS3_14087_1en_05/2022
Page 7
www.argo-hytos.com
3.6 Pressure drop related to flow rate
(measured at a viscosity of 32 mm
2
s
-1
)
Type of spool + curves P-A
P-B
A-T
B-T
P-T
Z11,R1,R21,X11,X32 1
1
2
2
C11
5
5
5
6
2
H11
1
1
1
2
2
Z51,H51
1
2
C51
1
2
4
R31
1
2
K11
1
2
R30
3
1
1
2
X30
1
1
2
3
V51
3
3
12
4
24
28
16
20
32
5
4
6
70
80
0
10
20
30
40
50
60
(21.1)
(18.5)
(7.9)
(2.6)
2
1
(120)
(175)
(60)
(350)
(406)
(235)
(290)
(464)
3
(5.3)
(10.6) (13.2) (15.9)
8
Flow Q [l/min (GPM)]
Pr
essur
e dr
op Δp [bar (PSI)]
3.7 Spool position sensor
1
2
4
3
Technical data
Max. pressure resistance
bar (PSI)
315 (dynamic)
Operating temperature
°C (°F)
-20 … +85 (-4 ... +185)
Storage temperature
°C (°F)
-25 … +85 (-13 ... +185)
Supply voltage Ub
V
24 V DC ± 20 %
Current consumption (max.)
mA
20
Output voltage (min.)
V
Ub – 2,5 V
Output current
mA
2 x 250
Ingress protection
IP65
Hysteresis of switching point (max.)
mm (in)
0,06 (0.002)
Reproducibility at 25 °C (77 °F)
mm (in)
± 0.02 (± 0.0008)
Temperature drift
mm / °C
0.002
Weight
kg (lbs)
0.25 (0.55)
4-pin connector with the thread M12
Function description:
Contactless inductive sensor with two transistor switched outputs. The output OUT 2 is inverted. The double output signal is protected against
mutual interference and increases the reliability of the spool end position signalization, which is important for the command system ensuring the
safety of the machine operation. The sensor is factory set to switch when the spool is moved from its base position by 0.5 ± 0.1 mm. The relative
position of the encoder parts after adjustment is indicated in red. The electrical connection of the sensor is provided by a four-pin connector with
M12x1 thread.
Ub
OUT 1
OUT 2
GND
AC
DC
DC st
Oscil
DC
1
1
4
2
3
1
1
0,5 0,1 mm
±
0
0
0
2,5 mm
(0,2±0,04 in)
Connection scheme of the spool position sensor
Contact switching diagram
0 - max. voltage 1,8 V DC
1 - min. voltage Ub – 2,5 V DC
←
Adjusted switching point
Pin 4
Pin 2
(0,98 in), spool switched by solenoid