background image

Operating_Instructions_RPE3-062x/xS3_14087_1en_05/2022

Page 1

www.argo-hytos.com

ARGO-HYTOS s.r.o.
Dělnická 1306, CZ 543 01 VRCHLABÍ

[email protected]

        + 420 499 403 111

Original instruction manual 14087_1en_de_cz_06/2022, issued by the manufacturer: 

Important!

 

Read the instructions carefully before using the product. 

Keep instructions for further reference.

If the instruction manual is lost, it can be downloaded from the ARGO-HYTOS website

 www.argo-hytos.com

.

4/2 HYDRAULIC DIRECTIONAL CONTROL VALVE WITH AXIAL SPOOL 
POSITION SENSOR, SOLENOID OPERATED, 
SUITABLE FOR USE AS A SAFETY COMPONENT 
WITH CERTIFIED FUNCTIONAL SAFETY

RPE3-062x/xS3

Operating instructions

EN

Summary of Contents for RPE3-062 S3 Series

Page 1: ...the manufacturer Important Read the instructions carefully before using the product Keep instructions for further reference If the instruction manual is lost it can be downloaded from the ARGO HYTOS...

Page 2: ...Operating_Instructions_RPE3 062x xS3_14087_1en_05 2022 Page 2 www argo hytos com...

Page 3: ...e coil 14 6 7 Product maintenance 14 6 7 1 Continuous valve inspection 14 6 7 2 Checking the function of the position sensor 14 6 8 Spare parts supplied 15 6 9 Product disposal 15 7 Manufacturer conta...

Page 4: ...ndicate the limit combinations of pressure and volume flow at which reliable valve operation is still ensured 4 2 is the abbreviated designation of the valve description Four means that it is a four w...

Page 5: ...function Correct function of the position sensor is guaranteed only to a emperature of 85 C Translated with www DeepL com Translator free version CAUTION Surface temperature of the valve The surface t...

Page 6: ...eal material C 30 to 80 Working fluid temperature range for FPM seal material C 20 to 80 Ambient temperature range C 30 to 50 Working fluid kinematic viscosity range mm2 s 1 10 to 400 Required minimum...

Page 7: ...0 06 0 002 Reproducibility at 25 C 77 F mm in 0 02 0 0008 Temperature drift mm C 0 002 Weight kg lbs 0 25 0 55 4 pin connector with the thread M12 Function description Contactless inductive sensor wi...

Page 8: ...ulations and standards used SN EN ISO 12100 2011 Machine safety risk analysis ISO 4401 2005 Hydraulic fluid power Four port directional control valves Mounting surfaces SN EN ISO 9227 2017 Corrosion t...

Page 9: ...s must be ordered separately Tightening torque is 8 9 1 Nm 7 0 7 Ibf ft Besides the commonly used valve versions shown other special models are available Contact our technical support for their identi...

Page 10: ...ity for correctness and quality as this is a dangerous area of product use Elektrick p ipojen elektromagnetu a sn ma e polohy sm prov d t jen osoba s odpov daj c elektrotechnickou kvalifikac minors th...

Page 11: ...l valve in mm in Ports P A B T max 7 5 mm 0 29 in Connection surface free of mechanical damage indentations etc and dirt Mounting for DN 06 ISO 4401 03 02 0 05 Requirements for flatness and surface ro...

Page 12: ...isk of electric shock and short circuiting of the electrical equipment Control solenoid coils are designed for continuous operation 100 ED The coils have been assessed for compliance with Directive 20...

Page 13: ...rking fluid and contamination of persons WARNING Disconnecting the power supply Disconnect the electrical parts of the valve from the power supply There is a risk of electric shock and unintentio nal...

Page 14: ...circuit Disconnect the plug of the coil connector Make sure that the inner area of the socket with the contacts in particular is not dirty and contaminated with working fluid Remove the plastic nut at...

Page 15: ...h the applicable regulations The valve is mainly made of recyclable materials carbon steel cap PE see chapter 3 1 Materials used 7 Manufacturer contact ARGO HYTOS s r o D lnick 1306 CZ 543 01 VRCHLAB...

Reviews: