![Argo-Hytos FA 008 Operating Manual Download Page 28](http://html1.mh-extra.com/html/argo-hytos/fa-008/fa-008_operating-manual_2967794028.webp)
Subject to change · 33143400 · 05.2016 · EN
Page 28
www.argo-hytos.com
15.2 Fault table
Problem / fault
Possible cause
Elimination
›
Electric motor does not
turn on during
commissioning
Electrical cable or mains plug
defective
Have the cable replaced by a skilled electrician
Supply voltage missing
Establish the power supply or activate the electric fuse
On/off switch defective
Replace on/off switch
Motor defective
Replace motor (repair at the manufacturer's premises)
Pump defective
Replace pump (repair at the manufacturer's premises)
Viscosity too high (medium)
Warm up the oil
›
Electric motor switches
off during operation
Electric motor overheated
Let the motor cool down, clean any contaminated ventilation
slits
Pump blocked
Replace pump (repair at the manufacturer's premises)
›
Volume flow is clearly
too low
Filter element contaminated
Let the motor cool down, clean any contaminated ventilation
slits
Pump blocked
Replace pump (repair at the manufacturer's premises)
›
Volume flow is clearly
too low
Filter element contaminated
Replace filter element
Suction strainer contaminated
Replace / clean suction strainer
Viscosity too high
Warm up the medium
Suction height too large
Adjust suction height
Leak on the suction side
Replace suction hose or seal connection points (re-tighten them)
Wear of the pump
Replace pump (repair at the manufacturer's premises)
›
Operating noise too loud Filter element contaminated
Replace filter element
Suction strainer contaminated
Replace / clean suction strainer
Viscosity too high
Warm up the medium
Suction height too large
Adjust suction height
Leak on the suction side
Replace suction hose or seal connection points (re-tighten them)
Wear of the pump
Replace pump
Filter unit standing on a vibration-
sensitive surface (e.g. sheet metal)
Improve site conditions
›
Pump does not suck
Leak on the suction side
Replace suction hose or seal connection points (re-tighten them)
Unit pumped empty
(with refilling)
Prime the unit (0.3 l)
Suction strainer clogged
Clean / replace suction strainer
›
Oil on the fan wheel
cover
›
Oil leaking out of
terminal box
Shaft seal leaky
Replace motor (repair at the manufacturer's premises)
Residual oil at the housing after
filter element change
Clean filter unit
Screwing leaky
Check the screw joints, re-tighten and / or seal them
Table 7: Fault table