Argo-Hytos FA 008 Operating Manual Download Page 1

Subject to change · 33143400 · 05.2016 · EN

Page 1

www.argo-hytos.com

Safety and operating instructions

Read safety and operating instructions before use.

Note:

 The indicated data only serve to describe the product.

Information regarding the use of this product are only examples and suggestions.
Catalog specifications are no guaranteed features.
The information given does not release the user from his / her own assessments and inspection.

Our products are subject to a process of natural wear and aging.

© All rights are reserved by ARGO-HYTOS GMBH, even in the event of industrial property rights.
Any right of disposal such as copying and distribution rights shall remain with us.

The picture on the title page shows a configuration example.  
The delivered product may thus differ from the illustration.

Filter Unit

FA 008

Operating Manual

Summary of Contents for FA 008

Page 1: ...re no guaranteed features The information given does not release the user from his her own assessments and inspection Our products are subject to a process of natural wear and aging All rights are res...

Page 2: ...8 4 Scope of delivery 9 5 About this product 10 5 1 Performance specification 10 5 2 Device description 10 5 3 Component overview 10 5 4 Identification of the product 11 6 Transport and storage 12 6 1...

Page 3: ...or 22 11 Decommissioning 23 12 Disassembly 24 13 Disposal 25 14 Extension 26 14 1 Optional accessories 26 14 1 1 Hose extensions 26 15 Troubleshooting 27 15 1 How to proceed 27 15 2 Fault table 28 16...

Page 4: ...ct we use standardized safety instructions symbols terms and abbreviations For better understanding these are explained in the following sections 1 3 1 Safety instructions In this documentation safety...

Page 5: ...indicates danger to equipment material and environment This symbol indicates the risk of personal injury minor injury This symbol indicates the risk of personal injury death serious bodily injury This...

Page 6: ...fety related applications unintended operating states may occur in the application which may cause personal injury and or property damage Therefore only use this product in safety related applications...

Page 7: ...ersonal injury and or material damage Therefore only use the product in safety relevant applications if this use is explicitly specified and permitted in the product documentation You may only put the...

Page 8: ...wear or malfunction Make sure that connections hydraulic lines and attachment parts e g gauges are free of dirt and chips Prior to commissioning check that all hydraulic and mechanical connections are...

Page 9: ...Subject to change 33143400 05 2016 EN Page 9 www argo hytos com 4 Scope of delivery The package includes 1 Filter Unit FA 008 1 Operating manual...

Page 10: ...systems The volume flow is 8 l min 50 Hz The operating temperature is in the range of 0 C to 65 C 5 2 Device description The filter unit FA 008 consists of a support frame in which a filter pump unit...

Page 11: ...change 33143400 05 2016 EN Page 11 www argo hytos com 5 4 Identification of the product 1 Max pressure 4 Year of manufacture 2 Nominal volume flow 5 Type designation 3 Filter fineness 6 Address Fig 2...

Page 12: ...o chemical reactions Risk of injury Chemical substances in the immediate vicinity of the filter unit may react and lead to destruction of the device and to injuries of persons who are in the immediate...

Page 13: ...pecified on the typeplate of the motor the power source has appropriately been secured the cross section is of sufficient size cable and connection to the power source are in perfect condition With 3...

Page 14: ...red hydraulic oil If this is not the case the filter unit must be cleaned and the filter element is to be replaced see filter element change When using the hoses during unmanned operation ensure that...

Page 15: ...ve strainer is removed the manufacturer will resume no liability 9 1 Filtering hydraulic fluids when refilling 1 Connect the filter unit to a power source 2 Place the suction strainer into the oil dru...

Page 16: ...er unit may take a few seconds 6 Using the clogging indicator check the element for clogging at operating temperature of the medium used 7 At the end of filtration pull the suction strainer out of the...

Page 17: ...with an oil binding medium Then immediately dispose of the oil binding medium according to the national environmental regulations Ignition hazard Risk of electrostatic charge by poorly conducting hydr...

Page 18: ...ow with clean filter element too loud noise level Table 6 Maintenance overview 10 2 1 Replacing the suction strainer NOTE Damage to the filter unit by missing or defective suction strainer Damage The...

Page 19: ...onmental legislation Waste code Oil filter 16 01 07 Fig 7 Attaching the filter element 10 3 3 Attaching the filter element 1 Check the filter element type number Does the load inscription on the filte...

Page 20: ...alling may only be carried out by qualified electricians Risk of injury Risk of injury by incorrect handling Uninstalling may only be carried out by instructed persons Fig 9 Replacing the motor and th...

Page 21: ...ssing the pump plate onto the motor please check that the O ring Pos 6 does not slide out of the O ring groove and will be damaged between motor and pump plate The hole for the pin rotation lock Pos 2...

Page 22: ...te 3 Attach the preassembled pump plate Pos 4 with Pos 5 onto the motor Insert the key of the motor shaft Pos 8 in one of the four key grooves of the inner rotor NOTE When pressing the pump plate onto...

Page 23: ...fied electricians Risk of injury Risk of injury by incorrect handling Uninstalling may only be carried out by instructed persons The final decommissioning and disposal requires complete uninstallation...

Page 24: ...Subject to change 33143400 05 2016 EN Page 24 www argo hytos com The filter unit is a device that does not need to be dismantled 12 Disassembly...

Page 25: ...er unit FA 008 and the hydraulic fluid can lead to environmental pollution Therefore dispose of the filter unit and the hydraulic fluid in accordance with the national regulations of your country Disp...

Page 26: ...n strainer at the suction pipe cannot be used This is the case when the filter unit is to be mounted to the hydraulic unit by quick fitting coupling or ball valve or the opening of the tank is not suf...

Page 27: ...to detect changes in the overall system into which the product has been installed Have the operating conditions or the operating range of the product changed Have modifications e g conversions or rep...

Page 28: ...uction strainer contaminated Replace clean suction strainer Viscosity too high Warm up the medium Suction height too large Adjust suction height Leak on the suction side Replace suction hose or seal c...

Page 29: ...dicator Pressure gauge DG 200 16 green 0 2 7 bar red from 2 7 bar upwards Suction strainer mesh size m 300 Suction side Hose DN 20 with suction strainer length 1 8 m Pressure side Hose DN 20 with disc...

Page 30: ...total duration of 20 hours during the period of use of the unit 15 400 NOTE Varying viscosity behavior Viscosities of a medium are always temperature dependent Admissible suction heights m max first u...

Page 31: ...Subject to change 33143400 05 2016 EN Page 31 www argo hytos com 17 Appendix 17 1 EC Declaration of Conformity...

Page 32: ...S 6 Washer 8 4 4 DIN 00125 7 Hexagon nut M8 4 DIN 00934 8 Motor 1 FA 008 1700 9 Rubber buffer 4 FNA 008 0705 10 Washer 6 4 4 DIN 00125 11 Hexagon nut M6 4 DIN 00934 12 Distance piece 4 FA 008 0724 13...

Page 33: ...h Republic ARGO HYTOS GMBH info cz argo hytos com ARGO HYTOS Protech s r o info protech argo hytos com France ARGO HYTOS SARL info fr argo hytos com Germany ARGO HYTOS GMBH info de argo hytos com Grea...

Reviews: