and  connect  the  signal  from  DMX  controller  to  control 
the various functions of the projector.

When the projector is receiving a DMX frame, if the si­
gnal is lost (or the cable is disconnected) the projector 
holds the current levels of DMX channels and the LED 
source is still driven with the levels sent in the last valid 
DMX frame.
Then, if the projector is turned off and on, and it is not 
connected  to  a  valid  DMX  signal,  the  light  intensity  is 
brought  to  0%  (unless  you  changed  the  option  menu 
"manual" prior to switch off, see later in option settings).

Should the temperature of the LED board increase over 
85°C,  the  electronic  management  automatically  redu­
ces the light intensity in order to bring the temperature 
back to acceptable values.
In addition, the brightness of the light is brought to zero 
when  the  temperature  on  the  LED  board  rises  above 
100°C.

OPTION MENU

To  activate  the  display  press  any  button.  Then  to 
access  the  options  of  the  projector  press  the  MENU 
button.  The  display  shows  the  name  of  the  option 
starting  from  option  1,  the  base  DMX  address.  Press 
again  the  MENU  button  to  scroll  through  the  list  of 
options.  Adjust  the  value  with  UP  or  DOWN  buttons, 
then confirm your choice with ENTER (the display sho­
ws 

-STORED-

).

If you don't press ENTER, all your changes will be lost: 
after  20  seconds  of  inactivity  inside  the  options  menu, 
the display returns back to the idle state.

Option 1

 ­ 

DMX address

When  the  display  shows 

DMX  ADDR

  with  the  current 

DMX address, press the UP or DOWN buttons as ma­
ny times as required to display the number of the desi­
red channel. To fast forward press and hold the button. 
Remember  that  you  can  quickly  jump  to  the  minimum 
value (001) or the maximum possible value. To set the 
minimum,  press  UP  while  pressing  DOWN;  to  set  the 
maximum, press DOWN while pressing UP.
Press ENTER to store or MENU to go back.

Option 2

 ­ 

Manual level settings

Manual  settings  are  only  effective  when  there  is  no 
DMX  signal  connected,  instead  they  have  no  effect 
when  the  DMX  signal  is  present  (message 

-ERROR-

 

shown).
When the display shows 

MANUAL

, in the second row it 

shows  the  channel  number  (starting  from  1)  and  the 
current  manually  set  level  in  DMX  units,  for  example 

CH1: 255

.

The channel number is blinking, while the channel level 
is steady. Use the UP or DOWN button to switch to the 
desired  channel  (1  to  2),  then  press  ENTER:  now  the 
channel  number  is  steady  and  the  channel  level  is 

blinking,  indicating  that  you  can  modify  its  value.  Use 
UP  or  DOWN  to  adjust  the  channel  level;  for  fast 
forward press and hold the button. Then press MENU 
to return to the channel selection.
Remember  that  you  can  quickly  jump  to  the  minimum 
value (001) or the maximum value (255). To set the mi­
nimum, press UP while pressing DOWN; to set the ma­
ximum, press DOWN while pressing UP.
Repeat  the  above  steps  until  you  finish  your  manual 
settings.  Finally  press  ENTER  to  save  your  job,  the 
display shows 

-STORED-

.

The values are stored into the permanent memory, and 
will be reproduced until you connect the DMX signal.

Note:

After you set the manual values, when the projector is 
turned  off  and  on,  and  it  is  not  connected  to  a  valid 
DMX signal, the channels levels for ch.1, ch.2 are auto­
matically recalled from memory and the LED source will 
behave accordingly. 
If  you  connect  a  DMX  signal  and  then  remove  it,  the 
stored  values  become  "disabled"  and  at  the  next  igni­
tion  (without  DMX)  the  manual  values  will  be  ignored; 
the light intensity is brought to 0%, while ch.2 is set to 0.
In all cases, if you switch on the projector with a valid 
DMX  signal  connected,  the  manual  settings  are  igno­
red.
Remember  that  if  you  don't  press  ENTER  to  save  in 
memory, the manual settings will be lost and won't be 
recalled at the next power on.

Option 3

 ­ 

Fan Mode

This  function  relates  to  the  control  of  the  LED  cooling 
fan.
When  the  display  shows 

FAN MODE

,  the  second  row 

shows the current operating mode and you can change 
it by pressing UP or DOWN button:

­ 

MAX

The fan is always on at maximum speed.

­ 

OFF-MAX

The fan is switched off until the temperature is below a 
minimum setpoint (50°C), then it starts blowing at mini­
mum  speed  and  gradually  increases  in  speed  as  the 
temperature  rises,  reaching  the  maximum  speed  at 
70°C.

­ 

MIN-MAX

The  fan  is  always  on  at  minimum  speed  when  the 
temperature  is  below  a  minimum  setpoint  (50°C),  and 
gradually increases in speed as the temperature rises, 
reaching the maximum speed at 70°C.

Press  ENTER  to  confirm  (the  display  shows 

-STORED-

 for a while) or press MENU to quit.

Option 4

 ­ 

Software Version

When the display shows 

SW REV.

 you can read in the 

second  row  the  current  software  release  installed  on 

Summary of Contents for BARIO LED

Page 1: ...n areas of high humidity The unit is intended only for indoor purposes Avoid installing the unit close to heat sources Never lean the power cord on hot unit surfaces Allowed to be mounted directly on inflammable surfaces Keep a minimum distance of 3m between the device and the illuminated surfaces Avoid direct exposure to the light from the lamp The light luminance is harmful to the eye Install th...

Page 2: ...ake sure the stand or structure to which you are setting the projector is secure and is able to bear the weight of each unit POWER SUPPLY MAINS Disconnect the mains voltage from the system Connect the power cord to the mains supply paying attention to the voltage and frequency indicated on the label Respect the L N E polarity indicated on the terminals color brown L blue N yellow green E It is ess...

Page 3: ...he casing of the plug The ca sing of the plug must not be in contact with other ob jects possible sources of disturbance The three terminals have the numbering referred to the poles of the XLR connectors normally used for the connection of the DMX pin 1 GND or braided screen pin 2 DATA or cold pole pin 3 DATA or hot pole Pin 4 and pin 5 are not connected Connect the signal coming from the controll...

Page 4: ...ast forward press and hold the button You can quickly jump to the minimum value 001 or the maximum value 511 To set the minimum press UP while pressing DOWN to set the maximum press DO WN while pressing UP Press ENTER to store the display shows STORED or press MENU to return The number of selectable base addresses from the electronic board ranges from 1 to 511 OPERATION After supplying the device ...

Page 5: ...H1 255 The channel number is blinking while the channel level is steady Use the UP or DOWN button to switch to the desired channel 1 to 2 then press ENTER now the channel number is steady and the channel level is blinking indicating that you can modify its value Use UP or DOWN to adjust the channel level for fast forward press and hold the button Then press MENU to return to the channel selection ...

Page 6: ...ensure that no two devices with the same UID will appear on the DMX512 network The recommended method for representing the UID in text is in hexadecimal format with a colon separating the Manufacturer ID and the Device ID An example of such would be mmmm dddddddd where mmmm is the Manufacturer ID in hexadecimal and dddddddd is the Device ID in hexadecimal Manufacturer ID for Arena Luci is 0x00B0 D...

Page 7: ...arameter is used to get or set the DMX512 start address Use your RDM controller s commands to set the desired DMX address Get Software Version Label SOFTWARE_VERSION_LABEL This parameter is used to get a descriptive ASCII text label for the device s operating software version The descriptive text returned by this parameter is intended for display to the user The label may be up to 32 cha racters B...

Page 8: ...aste but must be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is correctly disposed you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling The recycling of materials will help to conserve natural resources For more d...

Reviews: