Arctiko ULTF 220 Operating Instructions Manual Download Page 16

16

Wiring diagram ULTF 80

Control box

T3
T2

PT1000

PT1000

NTC

NTC

PT1000
PT1000

240V AC

100-

Summary of Contents for ULTF 220

Page 1: ...OPERATING INSTRUCTIONS ULTF 80 220 320 420...

Page 2: ...arting procedure Starting up the freezer Disconnecting the appliance Control Panel Default settings Setting icons Custom Settings Advanced Settings Service Settings Advanced Service Settings Status Ch...

Page 3: ...e of different refrigerant For more information please refer to the rating plate affixed on the freezer Precautions and general recommendations Keep ventilation openings in the appliance enclosure or...

Page 4: ...solid and flat substrate This will eliminate any vibration and irritating noise The freezer should be placed with at least 10 cm free to the sides at least 15 cm free at the back and at least 10 cm fr...

Page 5: ...ter gets into the electrical parts it may cause short circuiting 6 In the event of functional or electrical irregularities please contact an authorised servicing engineer Before Commissioning Clean th...

Page 6: ...4 5 6 7 8 USB Data download 1 Temperature indicator 2 Alarm indivator 3 Alarm icons 4 Compressor indication 5 Date indication 6 Hour indication 7 Ambient temperature indicator 8 Battery level 9 USB C...

Page 7: ...7 Setting icons Custom Settings Advanced Settings Advanced Service Settings Status Change Reset password Change Reset password Status Advanced Service Settings Advanced Settings Custom Settings...

Page 8: ...n alarm will occur on the unit and until it will be shown on the display The menu High temp alarm is the settings of the highest temperature the device must be in side before it comes with an alarm Th...

Page 9: ...l defrost the deftrost can be started immediately The menu Hysteresis is the setting of the different from the setpoint whwere the compressor will start and stop The menu Temp range limits is the sett...

Page 10: ...d Under the menu Probe inside unit the tempe rature of the sensor mounted inside the unit is displayed There is mounted a sensor as stan dard in the unit but it is possible to mount 3 sensors inside t...

Page 11: ...ossible to change the password for Customer Settings Advanced Settings and Advanced Service Settings Under Reset password it is possible to reset the pass word for the Customer Settings Advanced Setti...

Page 12: ...the display USB connected Download Data Place the USB pen drive in the connection on the display and press the button right for read data from the unit to the USB pen The Read data will be shown in t...

Page 13: ...unit The Low temperature alarm indicate that the temperature inside the unit is lower than permitted from setting of the unit The Probe eprom failure alarm indicate that the probe is not working The...

Page 14: ...en alarm Freezer 70 Probe eprom failure Freezer 90 Freezer Freezer Enable 14 Default settings Description Arctiko default settings Customer settings AdvancedSettings Password 0000 Hysteresis Freezer 0...

Page 15: ...moved with a scraper at regular intervals Remember safety gloves T r Pull out the plug and leave the lid open until the ice can be removed Remember safety gloves 5 The ice formed on the inside of the...

Page 16: ...16 Wiring diagram ULTF 80 Control box T3 T2 PT1000 PT1000 NTC NTC PT1000 PT1000 240V AC 100...

Page 17: ...17 Wiring diagram ULTF 220 Control box T3 T2 PT1000 PT1000 PT1000 PT1000 NTC NTC 240V AC 100...

Page 18: ...18 Wiring diagram ULTF 320 420 Control box Fan V PT1000 PT1000 PT1000 PT1000 NTC NTC T3 T2 240V AC 100...

Page 19: ...19...

Page 20: ...50 80 010 06 GB WWW ARCTIKO COM LAMMEFJORDSVEJ 5 DK 6715 ESBJERG N DENMARK TEL 45 70 20 03 28 FAX 45 70 20 03 29 INFO ARCTIKO COM WWW ARCTIKO COM...