background image

 

 

Cleaning & Maintenance 

 

  Ensure the water is changed every 24 hours – If the unit is not being 

used drain all the water from it using the plug on the base 

  Clean the interior & exterior with warm soapy water 

  Dry with a clean soft cloth 

  DO NOT submerge the ice maker in water or use water sprays to clean 

it 

  Always clean your Arctica Ice Maker daily 

  Periodically it is advised to run a full tank of water through the ice maker 

with lemon juice to remove any smell that might build up 

 

 
Troubleshooting 

 

Fault 

Possible Cause 

Solution 

Add Water indicator is on 
 

Lack of water 

Stop the ice maker, fill with 
water, press ON/OFF to 
restart the unit 

Ice Full indicator is on 

Ice basket is full 

Empty the ice basket and 
restart the unit 

No ice being formed 

Room or water temp is 
too high 
 
 
Pipe is blocked 

Room temp should be 
10-43c, water temp should 
be 8-32c 
 
Contact your Arctica 
distributor 

 
Transportation and Storage 
 

Please handle your ice maker with care to prevent any damage to the unit and 
internal parts. The ice maker should be stored somewhere which is ventilation 
and non-corrosive gas.   
 
Do not store any flammable objects near the equipment. 
 

Technical Information 

 

HEA653 – Arctica Ice Maker 

Voltage ~230v 50/60Hz 
Refrigerant : R134a/62g 
Weight : 9.2 kg 
Dimensions : 242 x 358 x 328mm 
 
 

Reviews: