Arctic Aire DDR050BECCDB Owner'S Use And Care Manual Download Page 12

There are two ways to remove collected water:

1.  Use the bucket

When the unit is off and the bucket is full, the unit will beep 8 times, the 
bucket full indicator light will 

fl

 ash, and the digital display shows P2. 

When the unit is on and the bucket is full, the compressor turns off and 
the fan turns off after drying the water off the condenser for 30 seconds. 
The unit will then beep 8 times and the bucket full indicator light will 

fl

 ash, and the digital display shows P2.

To empty the full bucket, slowly pull out the bucket. Grip the left and 
right handles securely, and carefully pull it straight out so water does 
not spill. Do not put the tank on the 

fl

 oor because the bottom of the 

bucket is uneven. Otherwise the bucket will fall and cause water to spill. 
Discard the water and return the bucket to the unit. The bucket must 
be placed and properly positioned for the dehumidi

fi

 er to operate. The 

machine will restart when the bucket is restored in its correct position.

Note: When you remove the bucket, do not touch any parts inside of 
the unit. Doing so may damage the product. Be sure to push the bucket 
gently all the way into the unit. Banging the bucket against anything or 
failing to push it in securely may cause the unit not to operate. When 
you remove the bucket, if there is some water inside the unit you must 
dry it. The power button fl ashes when the bucket is not properly in 
place. 

2. Continuous 

draining:

Water can be automatically emptied into a 

fl

 oor drain by attaching the 

unit to an ID 

 5/16” water hose with a OD:M=1 male threaded end (not 

included, a standard garden hose works well).

 

Install the drain hose 

onto the adaptor A (see B1). The adaptor is found in the accessory bag 
located in the bucket. Remove the plastic cover from the back drain 
outlet of the unit and set it aside. Remove the bucket, then insert the 
drain hose through the drain outlet of the unit and securely press it into 
the connector on the front of the unit (see B2 and B3).

Tighten the adaptor A and the unit by using two screws (found in the 
bucket). Install the female threaded end of the water hose into the adap-
tor A (see B4), then lead the water hose to the 

fl

 oor drain or a suitable 

drainage facility. Make sure the hose is secure so there are no leaks. Di-
rect the hose toward the drain, making sure that there are no kinks that 
will stop the water from 

fl

 owing. Place the end of the hose into the drain 

and make sure the end of the hose is level or declining to let the water 

fl

 ow smoothly. Place the bucket back in the unit and make sure that it is 

located correctly. Select the desired humidity setting and fan speed on 
the unit for continuous draining to start.

Accessories (for continuous drain):

Drain hose (1 pc)     Adaptor A (1 pc)      Screw (2 pc)

Operating Instructions

REMOVING COLLECTED WATER

A1.

 Pull the bucket out a little

A2.

 Hold both sides of the bucket with 

even strength, and pull it out from the 
unit. Pour the water out.

B1.

 

B2.

B3.

 

B4.

Drain hose

Adaptor A

Plastic cover

Drain hose 
subassembly

Connector

Drain hose

Water hose

Female thread 
end

9

Summary of Contents for DDR050BECCDB

Page 1: ...DE UTILIZACI N Y CUIDADO PARA EL PROPIETARIO MODEL MOD LE MODELO DANBY PRODUCTS LIMITED ONTARIO CANADA N1H 6Z9 DANBY PRODUCTS INC FINDLAY OHIO USA 45840 2016 12 09 DDR050BECCDB DDR070BECCDB PORTABLE...

Page 2: ...t de la responsabilit et l obligation du client de changer la prise existante pour la rendre conforme au Code national de l lectricit et aux codes et r gles locaux applicables La fiche de mise la terr...

Page 3: ...l utilizaci n y cuidado para el propietario 25 36 Bienvenido Instrucciones de seguridad importantes Instrucciones d instalaci n Caracter sticas Instrucciones operadoras Cuidado y maintenimiento Soluci...

Page 4: ...formation to obtain service under warranty To receive service you must provide the original receipt Model Number Serial Number Date of Purchase NEED HELP Before you call for service here are a few thi...

Page 5: ...ged directly into the aforementioned receptacle rated 110 120 V A C Do not connect the dehumidifier to a multiple socket outlet that is also being used for other electrical appliances FOR YOUR SAFETY...

Page 6: ...power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired Do not use a cord that shows cracks or abrasion damage along its length or at either the...

Page 7: ...ncy To achieve maximum operating efficiency from your dehumidifier the recommended room ambient operating temperatures should be between 5 C 41 F and 35 C 95 F To maintain efficiency the dehumidifier...

Page 8: ...For drier air press the button and set to a lower percentage value For more damp air press the button and set a higher percentage value 6 Timer Button Press to initiate the auto start and auto stop f...

Page 9: ...you protect your wood and carpet from such leakage IMPORTANT Never tamper with or attempt to defeat the water level safety float switch system Proper installation of the water tank is crucial in main...

Page 10: ...outlet the green power light will not light up until the on off button is pressed When the on off button is pressed the power light turns on and the dehumidifier automatically defaults to Display Cur...

Page 11: ...ending on your model Option A Grasp the filter handle and pull the filter out The filter will slide out easily Fig 2 Option B Remove the bucket and pull the filter downwards 2 Clean the filter thoroug...

Page 12: ...Water can be automatically emptied into a floor drain by attaching the unit to an ID 5 16 water hose with a OD M 1 male threaded end not included a standard garden hose works well Install the drain h...

Page 13: ...unt of mild detergent Swish it around in the bucket empty and rinse Note Do not use a dishwasher to clean the bucket After cleaning the bucket must be placed and properly positioned for the dehumidifi...

Page 14: ...ee the Location section See the Air filter section For drier air press the button and set to a lower per cent value Check that all doors windows and other openings are securely closed Install the dehu...

Page 15: ...rized Danby Service Depot as service must only be performed by a technician qualified and certified for warranty service by Danby Transpor tation charges to and from the service location are not prote...

Page 16: ...res si votre appareil a besoin d entretien ou pour les demandes de renseignements g n raux Pour b n ficier d une op ration de mainte nance ou de d pannage le re u original sera exig Num ro de mod le N...

Page 17: ...La fiche trois broches mise la masse sur le cordon d alimentation doit tre branch e directement dans la prise susmentionn e de puissance nominale 110 120 V c a Ne branchez pas le d shumidificateur un...

Page 18: ...du fabricant il ne doit pas tre r par N utilisez pas un cordon qui pr sente des fissures ou des dommages caus s par l abrasion soit sur le cordon lui m me soit l extr mit de la fiche ou du raccord Si...

Page 19: ...est important de se rappeler que l efficience d un d shumidificateur sera affect e influenc e par le taux auquel on laisse infiltrer de l air nouveau et humide humidit dans le m me espace la m me zone...

Page 20: ...ur le bouton et r glez un pourcentage inf rieur Pour un air plus humide appuyez sur le bouton et r glez un pourcentage plus lev 6 Bouton minuterie Appuyez dessus pour activer la fonction de d marrage...

Page 21: ...du d tecteur de temp rature D branchez l appareil et rebranchez le Si l erreur se r p te veuillez contacter un technicien P2 Le r servoir est plein ou le r servoir n est pas en bonne position Videz l...

Page 22: ...ssus contribue galement r duire l humidit relative de l air ambiant Remarque Pour assurer une performance optimale veuillez v rifier que l humidit de l appareil soit r gl e un minimum de 10 de moins q...

Page 23: ...llume Un nettoyage plus fr quent peut tre n cessaire en fonction de la qualit de l air int rieur Important Ne faites jamais fonctionner l appareil sans le filtre air ENLEVER LE FILTRE AIR 1 Il existe...

Page 24: ...pas bien positionn 2 Vidange continue L eau peut tre automatiquement vid e dans un siphon de sol en con nectant l appareil avec un tuyau d arrosage flexible de diam int 7 94 mm 5 16 po avec un embout...

Page 25: ...propre et ajoutez un peu de d tergent doux Remuez le m lange dans le r servoir videz le et rincez le Remarque Ne lavez pas le r servoir au lave vaisselle Apr s le nettoyage le r servoir doit tre mis...

Page 26: ...ir Pour obtenir un air plus sec appuyez sur la touche et r glez un pourcentage plus bas Assurez vous que les portes les fen tres et les autres ouver tures sont bien ferm es Installez le d shumidificat...

Page 27: ...echnicien qualifi et certifi pour effectuer un entretien couvert par la garantie de Danby Les frais de transport entre votre domicile et le lieu de l entretien ne sont pas couverts par la pr sente gar...

Page 28: ...i su inidad requiere servicio o para hacer consultas generales Para recibir servicio t cnico debe sonstrar el recibo original N mero de modelo N mero de serie Fecha de la compra NECESITA AYUDA Antes d...

Page 29: ...a un recept culo como el antes mencionado con potencia de 110 120 voltios de CA No conecte el deshumidificador a una salida de tomacorriente m ltiple que se utilice tambi n para otros artefactos el c...

Page 30: ...no reparar un cable de suministro de energ a da ado con un nuevo cable de suministro de energ a que se obtenga del fabricante No utilice un cable que presente grietas o da os por abrasi n en cualquie...

Page 31: ...recomendadas deben encontrarse entre los 5 C 41 F y los 35 C 95 F Es importante recordar que la eficacia de un deshumidificador se ver afectada o influenciada por la velocidad en que se permite que e...

Page 32: ...ventilador Establezca el control del ventilador en alto para una m xima extracci n de la hume dad Una vez extra da la humedad y si se prefiere un funcionamiento silencioso establezca el control del v...

Page 33: ...s una funci n de seguridad Cuando se vac a la cubeta o se la vuelve a colocar correctament el deshumidificador retomar su funcionamiento autom ticament NOTA Puede tardar varios minutos antes de que se...

Page 34: ...torno Este proceso tambi n contribuye a disminuir la humedad relativa del aire del entorno Nota Para obtener el rendimiento ptimo aseg rese de que la unidad est ajustada por lo menos a un 10 menos que...

Page 35: ...e ilumina la luz de control de filtro Se puede requerir una limpieza m s frecuente seg n la calidad de aire del interior IMPORTANTE Nunca haga funcionar la unidad sin el filtro de aire en su lugar EXT...

Page 36: ...ua 5 16 in ID con extremo roscado hembra OD M 1 no incluido una manguera de jard n est ndar funciona bien Instale la manguera de drenaje en el adaptador A como se muestra en B1 El adaptador se encuent...

Page 37: ...di y bacterias Llene una parte de la cubeta con agua limpia y a ada un poco de detergente suave Agite el agua en la cubeta vac e la cubeta y enju guela Nota No utilice un lavavajillas para limpiar la...

Page 38: ...presione el bot n y establezca un valor porcentual m s bajo Verifique que todas las puertas ventanas y otras aperturas est n bien cerradas Instale el deshumidificador lejos de la secadora La secadora...

Page 39: ...que se efect e el servicio t cnico no est n cubiertos por esta garant a y son de responsabilidad del comprador Durante los primeros 24 meses cualquier parte en buen estado de este producto que resulte...

Page 40: ...e la main lors de la commande de pi ce ou service Type de produit Num ro de mod le Num ro de pi ce Description de la pi ce Todas las piezas de reparaci n disponibles para la com pra o la orden especia...

Reviews: