4 Swivel Casters

The appliance comes with 4 swivel casters; 2 with
locks for front of unit and 2 without locks, for the back
of the unit. The casters allow the appliance to be
moved with ease, and then locked into place upon
final destination. (Refer to page 3 for instructions.)

Reversible Door Lock

The appliance comes with an outer cabinet mounted
door lock and two keys.  The lock can be mounted on
either side of the appliance depending on which side
the door swings open. A door mounted lock guard
has been provided for added security. (Refer to page 7
for instructions.)

Reversible Door

The door can be reversed (See Routine Maintenance
section) to provide either a right-hand swing or a left-
hand swing.

Adjustable Temperature Control

The adjustable thermostat control is located on the top
left panel inside the unit.

Interior Thermometer

The appliance comes with a thermometer to show
internal temperatures. The thermometer is to be hung
from the top adjustable shelf on the right hand side.

Interior Light

The appliance is equipped with a 40 watt bulb that
lights up when the door is opened.  If bulb goes bad
replace with bulb of same type and wattage. This is a
special bulb with a shatterproof coating. Use an NSF
certified bulb of the same type and wattage (can be
ordered from your Arctic Air Service Center at
1-800-490-9574  /  P/N 2163600900).

Routine Maintenance

Cleaning the Interior

Be sure to turn the temperature control to off and
unplug the electrical cord. Wash the inside surface of
the storage area with warm water and baking soda
solution (about one tablespoon of baking soda per
quart of water). Rinse thoroughly with clean, warm
water and wipe dry. The procedure can also be used
for cleaning the door gasket.  Wipe the stainless steel
cover plates  with Magic Clean Stainless Steel Cleaner
(can be ordered from your Arctic Air Service Center at
1-800-490-9574  /  P/N 218490900) or some other
stainless steel cleaner.

Cleaning the Exterior

Wipe the textured cabinet exterior occasionally with a
cloth dampened in mild detergent and water, rinse
and wipe dry with a soft cloth.  Wipe the stainless
steel door plate and toe grill with Magic Clean
Stainless Steel Cleaner or some other stainless steel
cleaner. Do not use razor blades or other sharp
instruments that can scratch the appliance surface
when removing adhesive labels. Any glue left from the
tape can be removed with a mixture of warm water
and mild detergent or touch the residue with the
sticky side of tape already removed. DO NOT REMOVE
THE SERIAL PLATE.

Summary of Contents for F22CW13

Page 1: ...l Information 2 Installation and Setup 3 Appliance Start Up 4 Features 4 Routine Maintenance 5 Reversing Door 6 Energy Conservation Measures 7 Avoid Service Checklist 8 Wiring Diagram 10 If You Need S...

Page 2: ...use these items to play Cartons covered with rugs bedspreads plastic sheets or stretch wrap may become airtight chambers and can quickly cause suffocation Remove all staples from the carton Staples c...

Page 3: ...uts See following illustration Electrical Information These guidelines must be followed to ensure that safety mechanisms in the design of this appliance will operate properly Refer to the serial plate...

Page 4: ...12 hours To set the time of defrost wait until the desired time to defrost With the notch on the timer knob aligned with the line on the bracket Figure A turn the defrost timer knob clockwise slowly T...

Page 5: ...s a special bulb with a shatterproof coating Use an NSF certified bulb of the same type and wattage can be ordered from your Arctic Air Service Center at 1 800 490 9574 P N 2163600900 Routine Maintena...

Page 6: ...Slightly loosen the two hex spacers that the toe plate screws were screwed into 3 Holding door securely closed remove three 3 hex head screws from the top hinge and flat spacer 4 Lift appliance door o...

Page 7: ...e cabinet Energy Conservation Measures The appliance is designed for efficiency with heavy foam insulation However there are things that the user can do to maintain the appliance in operating conditio...

Page 8: ...cause appliance to run longer in order to maintain desired temperature Temperature control is set too cold Turn the control to a warmer setting Allow several hours for the temperature to stabilize Tem...

Page 9: ...r is kept open too long or is opened too frequently Open the door less often Door is slightly open causing the cold air from inside the appliance to meet warm moist air from outside See Occurrence sec...

Page 10: ......