background image

6

Swivel Casters

The appliance comes with 2 swivel casters and 2
nonswivel casters (with brakes). The casters allow the
appliance to be moved with ease, and then locked into
place upon final destination. (Refer to page 4 for
instructions.)

Adjustable Temperature Control

The adjustable thermostat control is located on the top
left panel inside the unit.

Interior Thermometer

The appliance comes with a thermometer to show
internal temperatures. The thermometer is to be hung
from the top adjustable shelf on the right hand side.

Interior Light

• The appliance is equipped with a 17 watt

fluorescent lamp. A ballast - lamp mismatch may
result in poor or no performance.

• If lamp goes bad, replace with lamp of same type

and wattage. Also, replace a lamp that flickers
continuously. This could damage the ballast.

• Turning lights off, when not in use, will save energy.

However, frequent ON-OFF cycling will reduce the
lamp life.

• Use an NSF certified lamp (216659500), which can

be ordered from your Arctic Air Service Center by
calling 1-800-490-9574.

Routine Maintenance

Cleaning the Interior

Be sure to turn the temperature control to off and
unplug the electrical cord. Wash the inside surface of
the storage area with warm water and baking soda
solution (about one tablespoon of baking soda per
quart of water). Rinse thoroughly with clean, warm
water and wipe dry. The procedure can also be used
for cleaning the door gasket.  Wipe the stainless steel
cover plates  with Magic Clean Stainless Steel Cleaner
(can be ordered from your Arctic Air Service Center
 P/N 218490900) or some other stainless steel cleaner.

Cleaning the Exterior

Wipe the textured cabinet exterior occasionally with a
cloth dampened in mild detergent and water, rinse
and wipe dry with a soft cloth.  Wipe the stainless
steel door plate and toe grill with Magic Clean
Stainless Steel Cleaner or some other stainless steel
cleaner. Do not use razor blades or other sharp
instruments that can scratch the appliance surface
when removing adhesive labels. Any glue left from the
tape can be removed with a mixture of warm water
and mild detergent or touch the residue with the sticky
side of tape already removed. DO NOT REMOVE THE
SERIAL PLATE.

Condensate Pan

The condensate pan is in a fixed position and must not
be removed from under the cabinet. If the pan is
removed, condensate will drip onto the floor.

Summary of Contents for Artic Air Commerical Glass Door Refrigerator

Page 1: ...lectrical Information 3 Installation and Setup 4 Appliance Start Up 5 Features 5 Routine Maintenance 6 Avoid Service Checklist 7 Energy Conservation Measures 9 Wiring Diagram 9 If You Need Service 10...

Page 2: ...unpacked Children should never use these items for play Cartons covered with rugs bedspreads plastic sheets or stretch wrap may become airtight chambers and can quickly cause suffocation A child might...

Page 3: ...other electrical components 4 There are four casters in the caster kit The pair of casters to be used in the rear do not have brakes Place one of these casters over one of the bolts in the rear Place...

Page 4: ...ing The appliance is designed to defrost automatically every 12 hours To set the time of defrost wait until the desired time to defrost With the notch on the timer knob aligned with the line on the br...

Page 5: ...sure to turn the temperature control to off and unplug the electrical cord Wash the inside surface of the storage area with warm water and baking soda solution about one tablespoon of baking soda per...

Page 6: ...cause appliance to run longer in order to maintain desired temperature Temperature control is set too cold Turn the control to a warmer setting Allow several hours for the temperature to stabilize Tem...

Page 7: ...ms Door is kept open too long or is opened too frequently Open the door less often Door is slightly open causing the cold air from inside the appliance to meet warm moist air from outside See Occurren...

Page 8: ...safe product storage temperatures 2 Make sure the appliance is located to prevent direct exposure to sunlight air ducts etc 3 Keep the door closed except for normal use Inspect the door often to see t...

Page 9: ...e delivery slip or some other appropriate payment record The date on the bill establishes the warranty period should service be required If service is performed it is in your best interest toobtainand...

Page 10: ...ir s option the warranty part s In addition ARCTIC AIR warrants that the compressor shall be free from defects for a total period of five 5 years This warranty will be effective with the earliest of e...