UNDER-COUNTER REFRIGERATORS AND FREEZERS

MAINTENANCE

 DANGER

TURN OFF THE POWER SWITCH AND 
DISCONNECT THE UNIT FROM THE POWER 
SOURCE WHENEVER PERFORMING SERVICE/  
MAINTENANCE FUNCTIONS AND/OR 
CLEANING THE REFRIGERATED AREA.

Refrigerators and Freezers

Clean.the.interior.and.exterior.using.soap.and.warm.wa-

ter. If this is not sufficient, use ammonia and water or a 

nonabrasive.liquid.cleaner..When.cleaning.the.exterior,.
always.rub.with.the.stainless.steel.grain.to.avoid.marring.

the finish.

Do.not.use.an.abrasive.cleaner,.it.may.scratch.the.stain-
less.steel.and/or.the.plastic..Abrasive.cleaners.can.also.
damage.the.breaker.strips.and.gaskets.

Cleaning the Condenser Coil

Clean.the.condenser.coil.a.minimum.of.every.90.days..
If.there.is.a.large.amount.of.debris,.dust.or.grease.ac-
cumulation.prior.to.the.90.day.cycle,.reduce.the.cleaning.
cycle.to.every.30.days.

If.the.buildup.on.the.coil.consists.of.only.light.dust.and.
debris,. clean. the. condenser. coil. using. a. brush.. For.
heavier.dust.buildup,.use.a.vacuum.or.compressed.air.

If.heavy.grease.is.present.use.a.refrigeration.degreas-

ing agent designed specifically for the condenser coils. 

Spray. the. condenser. coil. with. degreasing. agent. and.
blow.through.with.compressed.air.

Failure. to. maintain. a. clean. condenser. coil. can. initially.
cause.high.temperatures.and.excessive.run.times..Con-
tinuous.operation.with.dirty.or.clogged.condenser.coils.
may.result.in.compressor.failures..Neglecting.the.con-
denser.coil.cleaning.procedures.will.void.any.warranties.
associated.with.the.compressor.

 CAUTION

Never use a high pressure water wash for this 
cleaning procedure as water can damage the 
electrical components located near or on the 
condenser coil. 

Stainless Steel Care and Cleaning 

Stainless. steel. contains. 70-80%. iron. which. will. rust.. It.
also.contains.1-30%.chromium.which.forms.an.invis-

ible passive film over the steel

’s.surface.that.acts.as.a.

corrosion.shield..As.long.as.the.protective.layer.remains.

intact, the metal remains stainless. If the film is broken 

or.contaminated,.outside.elements.can.break.down.the.
steel.and.begin.to.form.rust.or.discoloration.

To.properly.clean.stainless.steel,.use.soft.cloths.or.plas-
tic.scouring.pads.

 CAUTION

Never use steel pads, wire brushes or scrapers to 
clean stainless steel surfaces.

Cleaning.solutions.must.be.alkaline.based.or.non-chlo-
ride.cleaners..Any.cleaner.containing.chlorides.will.dam-

age the stainless steel protective film. Chlorides are also 

commonly.found.in.hard.water,.salts,.and.household.and.
industrial.cleaners..If.cleaners.containing.chlorides.are.
used,. be. sure. to. rinse. repeatedly. and. dry. thoroughly.
upon.completion.

Perform.routine.stainless.steel.cleaning.with.soap.and.
water..Extreme.stains.or.grease.should.be.cleaned.with.
a.non-abrasive.cleaner.and.plastic.scrub.pad.(rub.with.
the.grain)..There.are.also.stainless.steel.cleaners.avail-
able.which.can.restore.the.protective.layer.and.preserve.

the finish.

Early.signs.of.stainless.steel.breakdown.may.consist.of.
small.pits.and.cracks..If.these.early.signs.are.present,.

clean  thoroughly  and  apply  a  cleaner  specifically  de

-

signed.for.stainless.steel.cleaners.to.attempt.to.restore.
the.passivity.

 CAUTION

Never use an acid based cleaning solution. In 
addition, many food products have an acidic 
content which can deteriorate the finish. Be sure 
to clean the stainless steel surfaces of all food 
products. Common acidic based food items 
include; tomatoes, peppers and other vegetables.

Summary of Contents for APP-48R

Page 1: ...ENANCE MANUAL Pizza Prep Tables Sandwich Salad Units Under counter Refrigerators and Freezers Worktop Refrigerators and Freezers IMPORTANT Please read this manual completely before attempting to insta...

Page 2: ...ay the set point 9 Change the set point 9 Manual Defrost 9 Keyboard Lock 9 Keyboard Unlock 9 Alarm Codes 9 Display and Reset Alarm 9 MAINTENANCE 10 Refrigerators and Freezers 10 Cleaning the Condenser...

Page 3: ...CHARGE Oz SHIP WEIGHT Lbs NEMA PLUG AST 28R 115 60 1 5 7 8 14 3 8 3200 9 5 276 5 15P AST 48R 115 60 1 7 12 12 26 1 2 5400 9 5 313 5 15P UNDERCOUNTER WORKTOP REFRIGERATORS MODEL V Hz Ph AMPS STORAGE CA...

Page 4: ...REGISTRATION The installation date and appliance model must be documented by the end purchaser Also refer to the Warranty section for additional details on registering the appliance Dealer Informatio...

Page 5: ...tate and federal regulations WARNING Make sure all facility electrical connections are in compliance with all local and federal electrical code regulations Inspection and Maintenance WARNING Appliance...

Page 6: ...g unloading and on site transporting 1 Visually inspect the exterior of the package skid and or container Report any damage to the carrier immediately 2 If any packaging damage is noted open and inspe...

Page 7: ...e or back for any reason allow a minimum of 24 hours in the upright position before start up to allow compressor oil to flow back to the sump Failure to meet this requirement can cause compressor fail...

Page 8: ...and Indicators The front panel controls and indicators are used to set and display the unit functions and status 1 1a 8a 3a 2a 2 8 7 4 5 6 3 Callout No Control Indicator Function 1 Fan Indicates the f...

Page 9: ...rd is locked With the keyboard locked only the set point or the max min temperature is displayed 3 If any key is pressed for more than three seconds the POF message is displayed Keyboard Unlock Press...

Page 10: ...an damage the electrical components located near or on the condenser coil Stainless Steel Care and Cleaning Stainless steel contains 70 80 iron which will rust It also contains 12 30 chromium which fo...

Page 11: ...onnected from the evaporator housing to the condensate evapora tor drain pan If water has collected underneath the unit check the condensate evaporator drain tube to be sure it is still located inside...

Page 12: ...12 Installation Operation Maintenance Manual WIRING DIAGRAMS Models APP 48R Models APP 71R AUC 27R AUC 48R AST 28R...

Page 13: ...13 UNDER COUNTER REFRIGERATORS AND FREEZERS Models Models AUC 27FZ AUC 48F AST 48R...

Page 14: ...14 Installation Operation Maintenance Manual Models APP 48R...

Page 15: ...15 UNDER COUNTER REFRIGERATORS AND FREEZERS Models APP 71R...

Page 16: ...16 Installation Operation Maintenance Manual Models AST 28R AUC 27R...

Page 17: ...17 UNDER COUNTER REFRIGERATORS AND FREEZERS Models AST 48R AUC 48R...

Page 18: ...18 Installation Operation Maintenance Manual Models AUC 27FZ...

Page 19: ...19 UNDER COUNTER REFRIGERATORS AND FREEZERS Models AUC 48F...

Page 20: ...unit and proof of purchase Service coverage is limited to units located in the United States and Canada only Limitations Exclusive Warranty This parts and labor warranty is the sole and exclusive war...

Page 21: ...Broich Enterprises Inc Arctic Air Eden Prairie MN 55344 Phone 952 941 2270 Fax 952 941 3066 Website www arcticairco com...

Reviews: