IMPORTANT NOTE:

The pH Neutralizing / Remineralizing Cartridge is there to increase the normally low pH (acidic) condensate water. In 

order to increase the pH, it also adds a certain amount of calcium carbonate, which increases the PPM/EC of water. As 

an example, if your condensate water is pH 6.0, the product water from the ARCS will be between 7.0-7.4 pH. Since the 

Heavy Metal Reduction Cartridge (stage 2) removes all PPM/EC, the product water after stage 3 will be between 40-75 

PPM (0.06-0.1 EC) of calcium carbonate. 

If you find your condensate water is within an acceptable range of pH before 

treatment and/or if you do not want any calcium carbonate in the product water, simply remove the stage 3 cartridge 

and leave that canister empty.

 

 

 

 

INSTALLATION GUIDE

The ARCS consists of the 3-stage Cartridge assembly, and 4th stage UV sterilizer mounted to the top of the bracket. The 

ARCS is designed to be placed on a level surface via its heavy duty floor stand or mounted to the wall as an option. The 

customer supplied pump should be placed within a 10-foot range of the ARCS.

1.  Prior to installation, inspect the ARCS for damage during shipping and call Hydrologic to report any issues.

2.  Shut down the HVAC system prior to plumbing. 

3.  Redirect the condensate runoff of the HVAC system(s) into a reservoir or storage tank of your choice. The 

customer supplied pump should be inline style, and must be able to handle system backpressure. The ideal 

flow rate of this pump should be 2 gallons per minute (GPM) with high head height. The ARCS has a flow 

restrictor that is set for 2 GPM so the water has enough contact time with the filters. Install the grey fitting on 

the left side of the unit. 

DO NOT

 over-tighten.

4.  Assemble and insert the UV lamp and Quartz sleeve (if needed) into the body of the UV as shown in the 

UV Installation Assembly on page 4.

5.  Plumb the outlet from the UV Filter to the reservoir or storage tank using all or part of the included blue 

2.

White inlet tubing

Grey fitting

White fitting

Black UV tubing

Blue product water tubing

Summary of Contents for HYDROLOGIC HL-11670

Page 1: ...ed solids 2 Residual oil from HVAC component s manufacturing process 3 Heavy Metals zinc copper lead etc The stages include 1 Stage 1 Sediment Cartridge Removes dirt oils and suspended solids 2 Stage 2 Heavy Metal Reduction Cartridge removes all heavy metals 3 Stage 3 pH Neutralizing Remineralizing Cartridge raises pH and adds calcium carbonate 4 Stage 4 Ultra Violet Sterilization kills pathogens ...

Page 2: ...face via its heavy duty floor stand or mounted to the wall as an option The customer supplied pump should be placed within a 10 foot range of the ARCS 1 Prior to installation inspect the ARCS for damage during shipping and call Hydrologic to report any issues 2 Shut down the HVAC system prior to plumbing 3 Redirect the condensate runoff of the HVAC system s into a reservoir or storage tank of your...

Page 3: ...produce quality water it is necessary to monitor the amount of water produced by the system Thiscanbedonewithaninlineflowmeter filtermonitorthatisavailableasanaccessory Withoutregularfilterchanges thequalityoftheproductwaterwilldrasticallydrop allowingharmfulbacteriaandmetalstobedischargedintoproduct water Stage1 SedimentCartridge replaceevery5 000gallons average Ifyounoticethecondensatewaterisunu...

Page 4: ... nut on the UV chamber To protect the o ring the nut should be snug but do not over tighten Step 6 Connect the UV lamp to the lamp socket Step 7 Carefully insert the UV lamp into the quartz sleeve through end nut Step 8 Install the cover cap and hand tighten onto end nut Step 9 The system should always be located closest to the point of use The UV kit can either be installed horizontally or vertic...

Page 5: ...ure to only use outlets with GFI protection 5 UV Specs 6 6 Consumed Power 22W 6 6 Input 110V 50 60Hz 6 6 Ambient Water Temperature 36 F 110 F 6 6 Iron 0 3ppm 0 3mg l 6 6 Hardness 7gpg 120mg l 6 6 Turbidity 1NTU 6 6 Manganese 0 05ppm 0 05mg l 6 6 UV Transmittance 75 The ARCS system is designed to ONLY treat condensate runoff water DO NOT attempt to use ARCS to treat any other water source To ensure...