OPERATION
25
(12) Welding current display
Display the pre-set or the actual welding current value.
Before the start of welding, the left-hand display shows the pre-set current value of Is, Iw, Ib and Ic.
After the start of welding, the left-hand display shows the present actual value of the welding current.
The control panel indicates which position has been reached in the welding process by brightening the light.
(13) Selection of arc start way in AC mode
(a) AC arc start: 1-ON, 2-OFF, 3-OFF
(b) DC arc start: 1-OFF, 2-OFF, 3-OFF
NOTE:
Only “Parameter selection keys” and “Adjusting dial” can be used in the welding process.
Only “Rod electrode welding key”, “Adjusting dial” and “AC/DC selecting key” can be used on MMA mode.
(14) Water cooling and gas cooling selecting key