Electrical Requirements
MUST BE ADHERED
1. The electrical components of the Neion Intelligent Toilet must be protected by a 10A RCD and
a 10A magnothermic switch. Both switches MUST be placed outside of the bathroom.
2. A fixed power connection must be connected by a dedicated flexible power cable consisting of
3 wires (active, neutral and earth) of a least 1mm
2
. The connection must be done inside an IPX4
or better junction box. If it is necessary to replace the power cable, this must be completed by a
qualified person.
NOTE: Any electrical work conducted on this product must be installed by a qualified person in accordance with
AS/NZ 3000 Wiring Rules.
Please consult with a qualified electrician to confirm an appropriate installation location.
No additional electrical equipment should be fitted inside the WC.
This product (IPX4) shall not be exposed to water jets for cleaning purposes.
D
According to current legislation
THIS MUST BE INSTALLED OUTSIDE
OF BATHROOM
min. 90
max. 200mm
90
Front view
3 x 1mm
2
L min. = 300mm
Min Ø6mm
Max Ø8.5mm
DANGER
10A