5634BIF User’s Manual
37
time can be limited as it is a country dependent
parameter.
S-Register
Range
Default
Description
S30
0-255
tens of
seconds
0
(disable)
Disconnect Inactivity Timer
Sets the length of time , in tens of seconds, that
the modem will stay online before disconnecting
when no data is sent or will reset the timer. The
timer is inoperative in synchronous mode.
S31
194
BIT Mapped Options Status
Bit 0
¡ Ð
Single line connect message
enable/disable(\Vn)
0=Message controlled by S95,
Wn and Vn (\V0)(Default)
1= Single line connect message
(\V1)
Bit 1
¡ Ð
Auto line speed detection (Nn)
0= Disabled (N0)
1= Enabled (N1) (Default)
Bits 2-3
¡ Ð
Error correction progress messages
(Wn)
0= DTE speed only (W0)
(Default)
1= Full reporting (W1)
2= DCE speed only (W2)
Bits 4-5
¡ Ð
Caller ID(#CID)
0=Caller ID disabled (#CID=0)
(Default)
1=Short (formatted) Caller ID
enabled (#CID=1)
2=Long (unformatted) Caller ID
enabled (#CID=1)
Bits 6-7
¡ Ð
Reserved
S32
0 - 255
11, hex
Sets the value of the XON character
S33
0 - 255
13, hex
Sets the value of the XOFF character
S36
Bit
Mapped
Bit 0-2
07, hex
LAPM Failure Control
This value indicates what should happen upon a
LAPM failure.
0
Modem disconnect.
1
Modem stays on-line and direct mode
connection is established.
3
Modem stays on-line and a normal mode
connection is established.
4
An MNP connection is attempted and if it
fail, the modem disconnects.
5
An MNP connection is attempted and if it
fails a direct mode connection is
established.
Summary of Contents for 5634BIF