4. 1+1 Redundancy

sing 1 more AQF600 as the redundant unit 

 

 

 

5. 1+N Redundancy: Using more AQF600 as the redundant units to increase the reliability 

 

 

 

We reserve the right to make alterations in the product materials and specifications without prior notification and consent to improve reliability, function or design or otherwise. 

Summary of Contents for AQF600 Series

Page 1: ...Ripple Noise max 1 Vout Efficiency typ 90 92 92 93 Hold up Time 12 ms min Protection Over Power Protection Auto recovery Over Voltage Protection Auto recovery Over Temperature Auto recovery Short Circuit Protection Latch off Isolation Input Output V AC 3000VAC or 4242VDC Input FG V AC 1500V Output FG V AC 500V Function 5V Stand by 18CFM FAN 5VSB 5V 0 6A Tolerance 10 Ripple Noise 100m Vp p max DC O...

Page 2: ...ions L x W x H 9 0 x 4 13 x 1 72 Inches 228 5 x 105 0 x 44 0 mm Tolerance 0 5 mm Weight 1024 50 g Cooling Integral fan Safety Agency Approvals CE UL60950 1 EMC EMI Conducted Radiated Emission EN 55032 class B Radiated Class A EMS Noise Immunity EN 55024 Surge 1KV L N 2KV L N FG NOTE 1 Ripple Noise are measured at 20MHz of bandwidth with 0 1uF 47uF parallel capacitor 2 Strongly recommend to conduct...

Page 3: ...2 0mm Customer is advised to screw into the threads no more than 2 0mm T 2 0mm Chassis of AQF600 Series Brands PIN Single Terminal 1 AC IN 2 4 DC OUT DINKLE DT 49 B01W 06 5 7 DC OUT Connector Pin CN4 Brands Cherng Weei JST PIN Single Mating Housing Terminal Mating Housing Terminal C1 S PHD H20 2X4P PHD T20 PHDR 08VS SPHD 001T P0 5 C2 S C3 CS C4 GND C5 GND C6 RC C7 PG C8 5V AUX Torque 3 0 5 Kgf cm ...

Page 4: ... by voltage output ground 4 5 5 5V referenced to pin C4 or C5 GND The maximum load current is 0 6A FUNCTION MANUAL APPLICATION NOTE 1 DC OK Signal Between DC OK pinC5 and GND pinC6 Output Status 3 7 5 7V ON 0 1V OFF 2 Remote Control It can be turned ON OFF by using the Remote Control function Between RC pinC3 and RC pinC4 Output Status SW ON Short OFF SW OFF Open ON 3 Current Share 1 Difference in...

Page 5: ... 26981319 5 4 1 1 Redundancy sing 1 more AQF600 as the redundant unit 5 1 N Redundancy Using more AQF600 as the redundant units to increase the reliability We reserve the right to make alterations in the product materials and specifications without prior notification and consent to improve reliability function or design or otherwise ...