Arch Environmental Equipment CTS 9000 IRRD Operation And Installation Manual Download Page 3

aintenance:

unit to trip.  When the unit trips the normally open contacts will close and the normally closed 
contacts will open or visa versa depending on which contacts are used.  If the CTS 9000 
IRRD is tripped and you wish to reset it, insure the rip in the conveyor belt has been fixed or 
the object has been removed from the belt.  Once the problem, which caused the trip, is 
corrected, press the wash button and clear the catch plate of any material.  Then reset the 
CTS 9000 IRRD by pressing the reset button.  The DELAY TIME SELECTOR in the control 
box can set the time that the infrared beam must be broken to trip the unit.  When the unit is 
tripped the lockout led will be illuminated and the trip led will be illuminated every time the 
infrared beam is broken. 

 
M

 

he CTS 9000 IRRD are dirty and you wish to clean them without tripping the 

rouble-Shooting:

If the covers of t
unit, press the wash button to disable the infra-red beam.  The amount of time needed to 
clean the lenses or wash down the unit can be set using the SET WASH TIME selector in 
the control box.  When the unit is in wash mode the wash led will be illuminated and the 
covers may be cleaned without tripping the unit.  An audible alarm will sound for 30 seconds 
before the unit returns to normal working operation..  
 

T

 

 

Is TRIP LED

Illuminated?

YES

Check All

Connections and

Power Source

Replace/Clean

Lens Covers

YES

Are Beams/Boxes

Misaligned

(Inside Boxes)

-Damaged-

Align/Replace

Boxes

Remove Covers

from Send/

Recieve Units

Does Unit Reset?

With Beam

Obstructed, will

Unit TRIP?

Return Unit to

Service

YES

Establish Reliable

Power Source

With Beam

Obstructed, will

Unit TRIP?

YES

YES

NO

NO

Consult
Factory

NO

NO

 

 

aintenance Schedule:

M

 

.    

It is recommended that all nuts, bolts, screws and connections be checked and    

 

1
           tightened every six months. 

Reviews: