12/EN
product. Type label is at the rear housing of
the product.
•
Power cable of your product must comply
with the values in "Technical specifications"
table.
DANGER:
Before starting any work on the
electrical installation, disconnect the
product from the mains supply.
There is the risk of electric shock!
Connecting the power cable
1. If it is not possible to disconnect all poles in
the supply power, a disconnection unit with
at least 3 mm contact clearance (fuses, line
safety switches, contactors) must be
connected and all the poles of this
disconnection unit must be adjacent to (not
above) the product in accordance with IEE
directives. Failure to obey this instruction
may cause operational problems and
invalidate the product warranty.
Additional protection by a residual current circuit
breaker is recommended.
If a cable is supplied with the product:
If a cable is supplied with the product:
If a cable is supplied with the product:
If a cable is supplied with the product:
2. For single
For single
For single
For single----phase connection,
phase connection,
phase connection,
phase connection, connect the
wires as identified below:
•
Brown/Black cable = L (Phase)
•
Blue/Grey cable = N (Neutral)
•
Green/yellow cable = (E)
(Ground)
Installing the product
When installing the hob onto a cabinet, a
shelf must be installed in order to separate
the cabinet from the hob as illustrated in the
above figure. This is not required when
installing onto a built-in oven.
For example, if it is possible to touch the bottom
of the product since it is installed onto a drawer,
this section must be covered with a wooden plate.
1
min. 50 mm
1. The sealing gasket provided in the package
must be applied on the lower casing bend
around the hob as shown in the figure,
during installation of the hob.
2. Place the hob on the counter and align it.
3. Using the installation clamps secure the hob
by fitting through the holes on the lower
casing.
For counters with a thickness of 30 mm, install
the clamps as illustrated below:
For counters with a thickness of 40 mm, install
the clamps as illustrated below:
If the thickness of the counter is less than 30
mm, insert a piece of wood to fill the gap
between the installation clamp and the counter.
When installing the hob onto a cabinet, a
shelf must be installed in order to separate
the cabinet from the hob as illustrated in the
above figure. This is not required when
installing onto a built-in oven.
Summary of Contents for OV 644 DB
Page 18: ...18 EN...