CI Guide Solo V1
Page
2 of 3
Pembroke Avenue, Waterbeach, Cambridge, CB5 9QR, England
Tel +44 (0) 1223 203200 Fax +44 (0) 1223 863384
Introduction
Solo
is an extremely flexible CI product and will allow for a very simple two-
zone setup with independent volume control for Zone 1 and Zone 2.
Solo
will require a remote pick-up device such as a Xantech Dinky Link
located within Zone 2 and a Power amplifier such as the signal sensing Arcam
P80 to complete the system.
The below diagram demonstrates the implementation of a external power
supply for a Xantech Dinky Link although the same wiring scheme will be
maintained for many other IR pick-up devices commonly available.
Dinky link
White stripe
Signal
+12v
0v
+12v
Tip = Signal
Slee ve = Ov
Zone 2
Solo Zone 2 IR input
Solo
also
has the ability to provide a
+12v trigger
for control of ancillary
devices such as power amplifier in the Second Zone; the +12v control is
active when the Solo is not in Off or Standby modes.