ARCA PIXEL 25 FC Instruction Manual Download Page 6

 

 

 

1.5  TECHNICAL DATA 

Size  

PIXEL 25 F C 

PIXEL 31 F C 

Type 

 C12-C32-C42-C52 

C12-C32-C42-C52

Nominal Heat Input to net calorific value (H

i

) referred (80 °C /60 °C) 

KW 

25 

31 

Minimum Het Input to net calorific value (H

i

) referred (80 °C /60 °C) 

KW 

10,5 

12,4 

Nominal Heat Output (80 °C/60 °C) 

KW 

24,4 

30,2 

Nominal Heat Output Condensing (50 °C/30 °C) 

KW 

26,9 

33,3 

Minimum Heat Output (80 °C/60 °C) 

KW 

10,1 

11,9 

Minimum Heat Output Condensing (50 °C/30 °C) 

KW 

10,7 

12,6 

EfficiencyRendimento (80 °C/60 °C) 

97,6 

97,5 

Partial Load efficiency (30 % of Pn) 

108,7 

107,9 

Nominal Heat Input (Pn) gas flowrate  

Natural gas G20 (2E+) 

m

3

/h 2,643 

3,278 

 

Natural gas G25 (2ELL) 

m

3

/h 3,0745 

3,812 

 LPG 

G30 

(3+) 

kg/h 

1,970 

2,443 

 

LPG  G31 (3P) 

kg/h 

1,941 

2,406 

Net gas pressure 

Natural gas G20 (2E+) 

mbar 

20/25 

20/25 

 

Natural gas G25 (2ELL) 

mbar 

20 

20 

 GPL 

G30 

(3+) 

mbar 

29 

29 

 

LPG  G31 (3P) 

mbar 

37 

37 

Pn flue gas temperature (80 °C / 60 °C) 

°C 

70 

74 

Pn flue gas temperature (50 °C / 30 °C) 

°C 

47 

51 

CO

2

 (G20) 

NOx (according par 6.2.2  of EN 483) 

mg/KWh

190 (classe 2) 

190 (classe 2) 

Losses of heat to the cheminey with burner ignited 

% 2,8 

3,0 

Losses of heat to the cheminey with burner not  ignited 

% 0,2 

0,1 

Losses of heat to the cover (

T = 50 °C) 

% 0,5 

0,5 

Flue gas flow rate  

Nm3/h

42,09 

53,03 

CENTRAL HEATING 

 

 

 

C.H. Minimum Set point 

°C 35 

35 

C.H. Maximum Set point 

°C 90 

90 

Volume of water in the boiler 

l 1,2 

1,2 

Volume of water of the expansion vessel 

l 7,5 

7,5 

Pressure of the expansion vessel 

bar 0,7 

0,7 

Least pressure in the primary circuit  

bar 0,4 

0,4 

Maximum pressure in the primary circuit  

bar 3 

Maximum content of heating water 

l 150 

150 

Available head at 1000 l/h of flow rate 

mbar 230 

330 

DOMESTICAL HOT WATER 

 

 

 

Minimum set point  

°C 

30 

30 

Maximum set point  

°C 

60 

60 

Production continuous warm water (T = 25 °C) 

l/min 

14 

17,3 

Production continuous warm water (T = 35 °C)  

l/min 

10 

12,4 

Water Volume(T = 30 °C during the first 10 minutes) 

116,6 

144,3 

Minimum flow  

l/min 

2,5 

2,5 

Maximum pressure  

bar 

Minimum pressure  

bar 

0,5 

0,5 

Voltage 

 ---- 

 ---- 

Frequency V/Hz 

230/50 

230/50 

Absorbed eletric power 

150 

150 

CONNECTION 

 

 

 

Flow connection C.H. 

Inch 

3/4" 

3/4" 

Flow connection D.H.W. 

Inch 

1/2" 

1/2" 

Gas connection 

Inch 

3/4" 

3/4" 

Height 

mm 720 

720 

Depth 

mm 300 

300 

Width  

mm 400 

400 

LENGHT OF FLUE GAS DUCTS 

 

 

 

Ø 60 x 100 mm coaxial 

Ø 80 mm doubled 

30 

30 

Ø 60 mm doubled 

 ---- 

 ---- 

Weight 

Kg 43 

43 

Degree of protection 

IP 

X4D 

X4D 

CE certification 

  

0068 

 0068 

 
 
 

Summary of Contents for PIXEL 25 FC

Page 1: ...To be used for INSTALLATION USE AND MAINTENANCE CONDENSING BOILERS PIXEL 25 FC PIXEL 31 FC IMPORTANT The first boiler ignition and the warranty have to be carried out by an authorised personnel LIB090...

Page 2: ...with inflammable substances Don t leave recipients of inflammable substances near the heater The electrical safety of the heater is assured only if it is linked to an ground system which is respectfu...

Page 3: ...nnections 13 2 5 Gas connection 14 2 6 Setting of control panel 15 2 7 Adjustement instructions nominal heat and minimal heat 16 2 7 1 Nominal heat adjustment 16 2 7 2 Minimal heat adjustment 16 2 8 S...

Page 4: ...r 9 valve of charging supply 10 vase of expansion 11 valve in three streets flussostatica 12 valve of discharging air 13 sanitary exchanger 14 condensing exchanger 15 condensing trap 16 Fan 1 3 AVAILA...

Page 5: ...C 5 Aluminium condensing exchanger Copper primary exchanger 6 Copper primary exchanger 7 Electrode of lighting and survey 8 Burner 9 Circulator 10 Gas valve 11 Safety valve 3 bar 12 Condensing trap 13...

Page 6: ...the cheminey with burner not ignited 0 2 0 1 Losses of heat to the cover T 50 C 0 5 0 5 Flue gas flow rate Nm3 h 42 09 53 03 CENTRAL HEATING C H Minimum Set point C 35 35 C H Maximum Set point C 90 90...

Page 7: ...LY SENSOR DHW MICRO SWITCH P1 P3 P2 TRANSDUCER OF PRESSURE OF HEATING SYSTEM AMBIENT THERMOSTAT REMOTE CONTROL OPTIONAL AIR PRESSOSTAT 3 1 GAS VALVE MODULATOR ELETTRODE OF LIGHTING AND SURVEY EXTERNAL...

Page 8: ...MODULATOR 1 3 AIR PRESSOSTAT AMBIENT THERMOSTAT REMOTE CONTROL OPTIONAL TRANSDUCER OF PRESSURE OF HEATING SYSTEM P2 P3 P1 SUPPLY SENSOR DHW SENSOR OPTIONAL L N GAS VALVE FAN PUMP FUSE 2 x 3 15 AF 5x20...

Page 9: ...CA have also a polipropilene version of flue gas ducts with resistance to the temperature of 120 C in continuous regime ARCA have not responsibility for every violation to the recommendations that are...

Page 10: ...ensing product flows into the boiler rather than to the outside 2 1 2 2 COAXIAL FLUE 60 x 100 mm N B The allowed lenght of coaxial flue ducts is by a minimum 0 5 meters to a maximum of 4 meters By 0 t...

Page 11: ...nsing product flows into the boiler rather than to the outside 2 1 3 2 COAXIAL FLUE 60 x 100 mm N B The allowed lenght of coaxial flue ducts is by a minimum 0 5 meters to a maximum of 4 meters By 0 to...

Page 12: ...their proper holes on the dimension plate inferior part after this it is possible to take away the dimension plate and use it other times hang the boiler through the previously set expansion hooks fo...

Page 13: ...oid the use of bends with reduced radius it is better to have a hot system cleaning in order to eliminate all the impurities coming from pipes and radiators particularly oil and fat substances which m...

Page 14: ...pes of gas In these conditions observe the gas meter counter for at least 10 minutes for verify that it doesn t signal any pas wise of gas Verify in each case all the line of gas with a solution or eq...

Page 15: ...inimum heating input 0 100 P8 oF external sensor off on external sensor on P9 K OTC 0 6 Pa type of boiler 0 domestical hot water and heating system boiler without tank and with 2 sensor 1 domestical h...

Page 16: ...T The boiler is delivered already set to the following values MET 30 mm H2O LPG 80 mm H2O Follow these instructions if you have to change these values open the domestic water to its maximal level and...

Page 17: ...21 25 13 1 30 1 8 13 3 BUTANE G30 116 09 28 30 13 0 72 5 27 PROPANE G31 88 37 13 0 72 6 2 34 6 2 11 INJECTORS PRESSURE TABLE PIXEL 31 F C Injectors diameters Diafr Gas Gas diaph P C I Inlet pressure...

Page 18: ...control the emission levels of CO CO2 and NOX in case of a boiler spare part replacement you should use only original spare parts by ARCA Arca refuses every kind of responsability about every damage c...

Page 19: ...is possible to plan the temperature desired of the circuit of heating acting counterclockwise in sense the lowest value of the available temperature is gotten Summer Winter Reset With the changer in...

Page 20: ...temperature 08 Air pressostat failure flue gas thermostat 09 Not water circulation 4 6 TEMPORARILY TURNING BOILER OFF You can achieve it by means of the room thermostat the MENU on the instrument pane...

Page 21: ...ION 3 Gas odour POSSIBLE CAUSES A Gas system leakage of both the internal and external pipe system REMEDIES A Close the main gas cock and call an expert SITUATION 4 Boiler condensation POSSIBLE CAUSES...