15
Issue Date: 12/4/2018
Activate Scene 3:
Press button 3 times. Amber LED will flash 3 times to confirm.
Deactivate Scene (ALL OFF):
Long press button for 2 seconds. Red LED flash 2 times.
LED 3 Times
LED 2 Times
SCENE SETUP / SCENE CONTROL
Page 1: ...INI KEY FOB REMOTE CONTROL MKFT 1704 CONTENTS 1 Overview and features Page 2 2 Diagrams Page 3 3 Battery Page 4 4 Pairing Un pairing device Page 6 5 Scene setup Scene control Page 7 6 Operation Page 16 7 Specifications Page 18 ...
Page 2: ...own the button to take control of the load level 3V CR2450 battery operation capable of 3 year battery life and built in battery low indicator Main features of remote control Compatible to L and M series Simple single and double click action 32 memories first in first out storage maintain Scene status memory create your desired atmosphere Actions are confirmed by the built in LED indication OVERVI...
Page 3: ...3 Issue Date 12 4 2018 2 Diagrams Notes for the diagrams DIAGRAMS Function Switch 1 Load Control 2 Scene Control 3 Scene Setup ...
Page 4: ...l flash once every 4 seconds to indicate the battery is low 1 With the mini key fob remote control bottom facing up use a slot screwdriver and gently lift open the battery compartment 2 Remove battery insulation strip First time use only BATTERY ...
Page 5: ...ment 4 Replace with a new 3V CR2450 battery and carefully align the 2 side hooks into the slot and push back the battery compartment LITHIUM BATTERY CAUTION Risk of Explosion if battery is replaced by an incorrect type Dispose of used batteries according to the environment protection rules BATTERY ...
Page 6: ...l that you wish to control for detailed pairing un pairing procedure With the receiver that you intent to use enter into Learning Mode Function switch at position 1 To Pair Press button once Green LED flash once To Un Pair Press button twice Red LED flash twice PAIRING UN PARING DEVICE LED Flash once LED Flash twice ...
Page 7: ...ither mini key fob mini one button remote or handy scene remote the M series receiver will know to activate whichever scene 1 2 3 to be called Because the memory is stored in the M series receiver so as long the M series remote control has been paired with the M series receiver the scene command will also work No need to reprogram each individual scene if you have 1 or more M series remote control...
Page 8: ...tion switch to position 3 4 Press button once to store Scene Status 1 5 Green LED flash 3 times Amber LED flash 1 time to confirm Scene 1 is stored Scene 2 1 Function switch at position 1 SCENE SETUP SCENE CONTROL LED 3 Times LED 1 Time ...
Page 9: ...esired load level status 3 Slide function switch to position 3 4 Press button twice to store Scene Status 2 5 Green LED flash 3 times Amber LED flash 2 times to confirm Scene 2 is stored LED 3 Times LED 2 Times SCENE SETUP SCENE CONTROL ...
Page 10: ...ition 1 2 Set the desired load level status 3 Slide function switch to position 3 4 Press button 3 times to store Scene Status 3 5 Green LED flash 3 times Amber LED flash 3 times to confirm Scene 3 is stored LED 3 Times LED 3 Times SCENE SETUP SCENE CONTROL ...
Page 11: ...ake sure the 2nd remote control is also paired to each individual receiver device that the mini key fob remote control is already paired to Scene 1 1 With the 2nd remote control set the desired load level status 2 On the mini key fob remote control slide function switch to position 3 3 Press button once to store Scene Status 1 4 Green LED flash 3 times Amber LED flash 1 time to confirm Scene 1 is ...
Page 12: ...desired load level status 2 On the mini key fob remote control slide function switch to position 3 3 Press button twice to store Scene Status 2 4 Green LED flash 3 times Amber LED flash 2 times to confirm Scene 2 is stored LED 3 Times LED 2 Times SCENE SETUP SCENE CONTROL ...
Page 13: ...esired load level status 2 On the mini key fob remote control slide function switch to position 3 3 Press button 3 times to store Scene Status 3 4 Green LED flash 3 times Amber LED flash 3 times to confirm Scene 3 is stored LED 3 Times LED 3 Times SCENE SETUP SCENE CONTROL ...
Page 14: ...NTROL Function switch at position 2 Activate Scene 1 Press button once Amber LED will flash 1 time to confirm Activate Scene 2 Press button twice Amber LED will flash 2 times to confirm LED 1 Time LED 2 Times SCENE SETUP SCENE CONTROL ...
Page 15: ...12 4 2018 Activate Scene 3 Press button 3 times Amber LED will flash 3 times to confirm Deactivate Scene ALL OFF Long press button for 2 seconds Red LED flash 2 times LED 3 Times LED 2 Times SCENE SETUP SCENE CONTROL ...
Page 16: ...tem receivers as ON OFF Dimmer function however scene control is not available Please refer to the relevant user guide for detailed operation SINGLE CONTROL Function switch at position 1 Turn the load ON Press button once Green LED flash once Turn the load OFF Press button twice Red LED flash twice OPERATION LED Flash once LED Flash twice ...
Page 17: ...t to adjust 3 Green LED will quick flash until button is released 4 At the desired level release button to stop During dimming process when the load level reaches to the lowest or brightest to continue dimming release button then press button again to start dimming Next time switching ON the load will return to the previous stipulated brightness OPERATION ...
Page 18: ... In accordance with Low Voltage Directive 2014 35 EU RED Directive 2014 53 EU CE Certification The CE marked affixed to this product confirms Its complaisance with the European Directives Which apply to the product and in particular its compliance with the harmonizes standards and specifications Dimension 53 x 37mm Weight 20 g Note Battery life is calculated at an average of 20 activations per day...