Flex 8ES/EX Standard, AB and Tandem Instruction Manual (CE)
November 2016
Page 27 of 45
4.2.3 Dipswitch Settings
4.2.3.1 Interlocked Pushbutton Pair
Interlocked means any pushbutton pair can not be pressed
simultaneously as it will cancel each other out. Interlocked
setting usually applies to electric motor’s forward & reverse
motion and On & Off switches. Each dipswitch on the
decoder board corresponds to a
pushbutton pair.
Dip
Settings
Function Descriptions
# of Relays
Used
00000000
Single speed only
2
00000010
4 output relays Closed/Closed relay action at 2
nd
speed
(separate 2
nd
speed output relays)
4
00000100
3 output relays Closed/Closed relay action at 2
nd
speed
(shared 2
nd
speed output relay)
3
00000110
4 output relays Opened/Closed relay action at 2
nd
speed
(separate 2
nd
speed output relays)
4
00001000
Forward (or Reverse) + Fast output relays engaged at 2
nd
speed
4
00001010
Forward (or Reverse) + Slow + Fast output relays engaged at 2
nd
speed
4
00001100
On (right button) & Off (left button)
2
00010010
On + Start/Off + Start - For added safety, you must first
rotate and hold the power switch key at START position and
then press the On or Off pushbutton to activate the output relay.
2
00001110
Magnet Lift On & Off
2
00010100
FWD/REV toggled (latching)
2
00100000
Single speed + External warning*
2
00100010
4 output relays Closed/Closed relay External warning*
4
00100100
3 output relays Closed/Closed relay External warning*
3
00100110
4 output relays Opened/Closed relay External warning*
4
01000010
4 output relays Closed/Closed relay Brake
4
01000100
3 output relays Closed/Closed relay Brake
3
01000110
4 output relays Opened/Closed relay Brake
4
01100010
4 output relays Closed/Closed relay Brake + External warning*
4
01100100
3 output relays Closed/Closed relay Brake + External warning*
3
01100110
4 output relays Opened/Closed relay Brake + External warning*
4
* External warning function requires installing an external warning device such as horn and lights to
the K26 Function output relay.