FUNCTIONS

MICRO INTELLECTUAL CONTROL 

ONE BUTTON TO CONTROL OPEN, STOP AND CLOSE. THE LIGHT WILL BE ON WHILE OPENING OR CLOSING THE DOOR, THREE MINUTES LATER 

THE LIGHT WILL BE OFF AUTOMATICALLY. CONTROL THE UNIT RUNNING BY COMPUTER PROGRAM. 

TEST THE FORCE OF OPEN OR CLOSE THE DOOR, THE UNIT HAS THE FUNCTION OF PHOTO BEAMS, AUTO-CLOSE, LOCK DOOR ETC.

THE DOOR WILL PAUSE MOMENTARILY THEN REBOUND WHEN IT REACHES THE HINDERS ON THE CLOSING WAY. THE UNIT HAS THE PROTECTING FUNCTIONS OF OVERLOAD, 
OVER HOT OR LOW POWER INPUT ETC.

DC MOTOR 

LOW NOISE, SOFT START, SLOW STOPPING TO PROTECT THE UNIT AND MAKE SURE IT CAN BE USED FOR A LONG TIME.

LED DISPLAY 

WORKING SITUATION CAN BE SHOWN ON THE LED SCREEN.

DECODING 

ROLLING CODE.

MANUAL DISENGAGEMENT 

OPEN AND CLOSE THE DOOR BY HAND WITHOUT POWER.

OPTIONAL FUNCTIONS 

PHOTO BEAMS, BATTERY BACKUP, WALL BUTTON AND FLASH LIGHT.

SPECIAL PROTECTION FUNCTIONS 

TRAVEL TIME PROTECTION, HALL COMPONENT PROTECTS AND LOW VOLTAGE PROTECTION.

TECHNICAL SPECIFICATIONS

Power input

220v ac +-10% 50-60hz

Reception frequency

433.92 MHz

Motor

24v DC

Decoding

Rolling Code

Working Temp

-20 - +50 c

Transmitter power

27A 12V battery

Relative humidity

<90%

Globe

LED

Open and Close Force

600n 800n 1000n 1200n

Courtesy light time

2 minutes

Summary of Contents for DG-O FORTE

Page 1: ...GARAGE DOOR OPENER INSTALLATION OWNERS MANUAL ARC DG O FORTE ...

Page 2: ... DC MOTOR LOW NOISE SOFT START SLOW STOPPING TO PROTECT THE UNIT AND MAKE SURE IT CAN BE USED FOR A LONG TIME LED DISPLAY WORKING SITUATION CAN BE SHOWN ON THE LED SCREEN DECODING ROLLING CODE MANUAL DISENGAGEMENT OPEN AND CLOSE THE DOOR BY HAND WITHOUT POWER OPTIONAL FUNCTIONS PHOTO BEAMS BATTERY BACKUP WALL BUTTON AND FLASH LIGHT SPECIAL PROTECTION FUNCTIONS TRAVEL TIME PROTECTION HALL COMPONENT...

Page 3: ...INSTALLATION RECOMMENDED TOOLS DRILL STEP LADDER RATCHET TAPE MEASURE CARPENTER S LEVEL SCREW DRIVER TONGS NEON ELECTROSCOPE MULTIMETER ADJUSTABLE WRENCH HAMMER INSTALLING THE OPERATOR AND RAIL ...

Page 4: ...CONTROL PANEL AND TRANSMITTER ...

Page 5: ...OPTIONAL TERMINALS AND CONNECTIONS ...

Page 6: ...ASH FU OR PREVENTING CODING MISTAKES IT IS NECESSARY TO CANCEL ALL STORED CODES TURN ON THE POWER LED DISPLAYS FROM 99 TO 11 AT LAST IT DISPLAYS SETTING OPEN AND CLOSE POSITIONS PRESS AND HOLD P UNTIL IT DISPLAYS P1 PRESS P IT DISPLAYS OP PRESS WHEN THE DOOR HAS REACHED THE OPEN POSITION PRESS P WHEN IT DISPLAYS FU PRESS AND HOLD C CODE THE DOT FLASHES KEEP MORE THAN 8 SECONDS UNTIL IT DISPLAYS DL...

Page 7: ... THIS FUNCTION AUTO CLOSE ON OFF PRESS AND HOLD P IT DISPLAYS P1 PRESS THREE TIMES IT DISPLAYS P4 PRESS P TO SHOW CURRENT SITUATION PRESS TO INCREASE THE AUTO CLOSE ONE MINUTE AND PRESS TO DECREASE ONE MINUTE MAXIMUM DEGREE IS B9 AND MINIMUM IS B0 PRESS P TO CONFIRM THE DEFAULT SETTING IS B0 B0 SHOWS AUTO CLOSE OFF LOCK DOOR WHEN YOU USE UNCOVERED TRANSMITTERS IT IS RECOMMENDED TO USE THE LOCK DOO...

Page 8: ...PARTS ARE IN GOOD WORKING CONDITION ADJUST THE TENSILE FORCE OF CHAIN ADD SUTIABLE AMOUNT OF LUBRICANT TO THE ACTIVE SYSTEM EXAMINATION GUIDE Problem Causes Solution The motor does not work The socket is not well connected or the fuse is broken Check the socket Replace the fuse After setting open close positions the motor does not work The screws of fixing the hall components are loose Program mis...

Reviews: