Arc-Zone A-PT-051-PRO Operation Manual Download Page 5

Arc-Zone.com, Inc.

2091 Las Palmas Drive, Ste. F

Carlsbad, CA  92011-1551 - USA

Tel. 760-931-1500    [email protected]

Copyright©2020, Arc-Zone.com®, Inc.  All Rights Reserved

ii 

ii 

SAFETY PRECAUTIONS

 

 

Please be warned that operation and maintenance of the system 

involve potential hazards. All operators and personnel should take 

precautions to prevent possible injury. 

 

Electrical safety 

Maintenance 

Machine

 

The counter, safety device against excess current and electrical 

installation, are compatible with its maximum power and its main voltage. 

The connection, single-phase or three-phase, is possible on a stand 

compatible with the plug of its cable link. 

If the cable is connected with the electrical network, the earth must never 

be cut by the protection device against electrical shocks. 

Work Place

 

Avoid contact between metal part and phase conductor and the neutral of 

electric network. 

Electrical messes of different electrical machine and apparatus are 

connected between themselves and with the terminal of earth neutral wire. 

Interventions

 

Before control and repair, see the apparatus is switched off and insulated. 

Connection with fixed installation cable is impossible. 

It’s on “Stop” and connection is impossible. 

Some apparatus are provided with starting circuit HT HF (with a plate). 

Never enter into the corresponding switch cupboard. 

Only qualified persons are authorized for intervention concerning electrical 

installation. 

Often check the insulation and connection good state of apparatus and 

electrical accessories

taps, appliance cords

coatings

switch

extension 

cords

etc. 

Maintenance and repair of insulating coatings operations are very 

important. 

Do repair with a specialist or better replace defective accessories. 

 Check regularly the right adjustment and the non-heating of electrical 

connections. 

WARNING

 

 

t

Safety Precautions:

Summary of Contents for A-PT-051-PRO

Page 1: ...1500 sales arc zone com Copyright 2020 Arc Zone com Inc All Rights Reserved A 8 A PT 051 PRO Benchtop Welding Positioner OPERATIONS MANUAL AND REPLACEMENT PARTS LIST operations operationsmanual manual...

Page 2: ...test...

Page 3: ...NTS Introduction Features Specification Function Install Operation Parts list Circuit Introduction i Safety precautions ii Limited warranty iii 1 General information 1 2 Specification 2 3 Function 4 4...

Page 4: ...ding rules for user safety before installing operating or servicing the equipment Equipment identification Receipt of equipment The identification number model and serial number of this unit can be fo...

Page 5: ...l part and phase conductor and the neutral of electric network Electrical messes of different electrical machine and apparatus are connected between themselves and with the terminal of earth neutral w...

Page 6: ...der this warranty policy is expressly limited to the replace or repair at its option of the defected part only ProArc s option to repair or replacement of a defected part under this warranty shall be...

Page 7: ...INFORMATION Features 1 High frequency interference tested 2 Tilting angle ranged from 0 90o for different welding application 3 Main shaft with 14mm through hole for pipe welding or shield gas 4 Face...

Page 8: ...del Unit PT 051 Power input 1 Phase 100 240VAC 50 60Hz 2Amp Capacity Horizontal Vertical kg 50 30 Rated eccentricity mm 30 Table dimension E mm 200 Rotation speed rpm 0 5 8 Spindle thru hole mm 14 Ear...

Page 9: ...Arc Zone com Inc 2091 Las Palmas Drive Ste F Carlsbad CA 92011 1551 USA Tel 760 931 1500 sales arc zone com Copyright 2020 Arc Zone com Inc All Rights Reserved 3 8 2 SPECIFICATION Distance Load C G...

Page 10: ...yright 2020 Arc Zone com Inc All Rights Reserved 4 8 4 3 FUNCTION No Description No Description 1 Stop button 6 Mounting Holes 2 Power switch 7 Power cord Power cord Adapter 3 Forward Reverse switch 8...

Page 11: ...ase Locking handle Turn clockwise to tighten lock turn counterclockwise to release Warning Do not turn the locking handle while loads are present on the faceplate 4 Power switch SW1 I On O Off 5 Forwa...

Page 12: ...late 1 11 0361 1009 9 PMDC Motor 1 12 5005 0110000 10 Worm reducer 1 13 0331 1207 Self Lubricating bearing 2 14 0140 0372 Machine mount 4 15 0130 0121 Handle 1 16 5034 5820900 10 Spacer 1 17 3214 2009...

Page 13: ...Arc Zone com Inc 2091 Las Palmas Drive Ste F Carlsbad CA 92011 1551 USA Tel 760 931 1500 sales arc zone com Copyright 2020 Arc Zone com Inc All Rights Reserved 7 8 7 5 PART LIST...

Page 14: ...rc Zone com Inc 2091 Las Palmas Drive Ste F Carlsbad CA 92011 1551 USA Tel 760 931 1500 sales arc zone com Copyright 2020 Arc Zone com Inc All Rights Reserved 8 8 6 CIRCUIT DIAGRAM t 6 Circuit Diagram...

Page 15: ...test2...

Page 16: ...Arc Zone com Inc 760 931 1500 sales arc zone com 2091 Las Palmas Drive Ste F Carlsbad CA 92011 USA...

Reviews: