15
English -
User guide
TMU
Dry-towel models
ZT, ZX, PUKITA, TUBÓN, DIJON, CUADRO, KARNAK, VERONA and ELFIE
1 - [+] Button
2 - Button [Prog].
3 - [On/stand-by] Button
4 - Button -
5 - Led screen (No retro-lightning).
A - Internal buzzer: For acoustic
warnings, compliant with EN60335-1
directive.
B - Water Protection: The IP44 protection
level is guaranteed by a special design of
the connection parts.
C - External sensor: Guarantees a stable
room temperature and a prompt reaction
in case of strong temperature variation.
Step 8
Connect the electronic control to the electrical net. Your towel radiator is ready for operation.
Step 4
Align the support stem
(b), with the support
base (a) and place the
towel radiator in its
position.
Step 5
Tighten the support
screw (h) with a
screwdriver.
Step 6
Insert the mini screw (i)
into the support base
(a) and tighten with a
screwdriver to fix the
bracket in the desired
position.
Step 7
Press and fit the trim (d)
in its position on the front
of the support (c).
Step 3
Without tightening completely, adjust
the support rod (b) to the towel radiator
with the front of the support (c) and the
support screw (h). Turn the support rod
(b) according to the following figures:
Straight Radiator
SCHEME OF THE THERMOSTAT
4
1
2
3
5
A
B
C
Curved Radiator