8.8 Setting Programmable Pulse Mode
67
8.8.3
Programmable Pulse: Pulse-Per-Hour Mode
Use the “PULSE PER HOUR?” mode to generate a pulse every hour, at the number of specified
seconds (from 0 to 3599 seconds) after the hour. Configure as illustrated in Figure 8.11. Refer to
Section 8.8 above for additional detail on the programmable pulse modes, and entering numerical
values.
For RS-232 commands, see Section 11.2.10
SET PROG. PULSE?
ENTER
SETUP
MODE
PULSE PER HOUR
DOWN
UP
ENTER
PULSE WIDTH
000.01
DOWN
UP
ENTER
600.00
|
000.01*
SECONDS AFTER HOUR
DOWN
UP
ENTER
3599
|
0000*
TIME
UTC
DOWN
UP
ENTER
LCL
UTC*
* = Default Setting
DCF77 modified
DCF77
SLOW CODE
SINGLE TRIGGER
IRIG-B
PULSE PER DAY
PULSE PER HOUR
SECONDS PER PULSE*
PROG. PULSE OFF
POLARITY
(+)
DOWN
UP
ENTER
(–)
(+)*
0000
Figure 8.11: Pulse-Per-Hour Setup