Service Menu
The service menu is only needed by service personnel to troubleshoot and to check
the system parameters. It is not accessible for normal users.
There are 4 service levels in which the system can be set.
• Level 0
: Normal system operation
• Level 1
: Turns off control panel beeper and siren (all other system operations will
remain the same).
• Level 2
: Like Level 1, but will turn off all alarm transmissions to the alarm
•
monitoring station except duress and personal attack. This service level
is only available to specific service users.
• Level 3
: Like Level 2, but turns off ALL alarm transmissions. This is normally used
for system update and is only available for specific service users.
If the system is in level 1, 2 or 3, the state is
displayed on all control panels of the system.
The service menu divides into two sub menus: “service mode” and “date/time”.
Users may often have access to “date/time” but access to “service mode” is restrict-
ed. If service mode is turned off (level 0) only a limited option menu is available:
In this mode, you can only go to the service mode selection menu or set the current
date / time (only available if no DCF-77 clock is installed in the system and no block
time is active in the system)
Read more about the functions in Service Mode in the
NOX user manual.