Terminal block 

Terminal 

Function 

12V 

0V 

Data 0 

Data 1 

IN 0 

IN 1 

 

NOX Specific Tip: 

Please make sure not to use PIN 1 on the CMU to supply the unit. The unit has a high peak current when 
calls are initiated. On the CMU you can use the BUS supply voltage, or an external supply.  

 

If an external power supply is used, please remember to connect ground on the Wiegand controller with 

the external supply’s ground to make sure the Wiegand signals work correctly. 

 

DIP-Switch 

Switch 

ON 

OFF 

4bit Bust for keypress 

8bit burst for keypress 

32bit Wiegand Output 

50bit Wiegand Output 

Listening mode ON 

Listening mode OFF 

 

Listening mode OFF: 

When the unit receives a call, it hangs up the call and sends the incoming phone number on the Wiegand 

bus 

Listening mode ON: 

When Listening mode is ON the call will be answered and the welcome message is played.  

The user can then input keys and finish by hitting the # key 

The unit will play a message depending on the state of IN0 and IN1. 

If the unit does not see a # key it will timeout with a message, and hang up. 

 

 