Page 1: ...310 SERIES LAYER 2 MANAGED NETWORK SWITCHES Quick Start Guide AN 310 SW F R 8 AN 310 SW F R 16 AN 310 SW F R 24 AN 310 SW F 48 AN 310 SW F R 8 POE AN 310 SW F R 16 POE AN 310 SW F R 24 POE ...
Page 2: ......
Page 3: ... may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not inst...
Page 4: ...ay be required to take adequate measures UL Statement All models have been evaluated by UL This device is intended for indoor use only It should not be connected to an Ethernet network with outside plant routing The user must use the class I optical transceivers which conform to U S code of federal regulation 21 CFR 1040 This equipment is only to be connected to PoE networks without routing to out...
Page 5: ...ern aesthetics and a managed Layer 2 interface the Araknis 310 series switch is a sleek and highly capable addition to any network Series Overview Model Ethernet Ports SFP Ports PoE Budget Watts AN 310 SW F R 8 8 2 AN 310 SW F R 16 16 2 AN 310 SW F R 24 24 2 AN 310 SW F 48 48 4 AN 310 SW F R 8 POE 8 2 130w AN 310 SW F R 16 POE 16 2 250w AN 310 SW F R 24 POE 24 2 375w NOTE All PoE models support bo...
Page 6: ...6 Araknis Networks 310 Series Layer 2 Managed Network Switches Quick Start Guide Step 1 Unbox Switch 1 Quick Start Guide Rubber Feet for Flat Surfaces 4 Rack Mount Kit Ears 2 Screws 8 AC Power Cord ...
Page 7: ...nt A B C NOTES Do not stack other equipment on top of the switch to avoid possible interference or damage Mounting is the same for models with both front and rear facing ports For the AN 310 SW F R 24 POE and AN 310 SW F 48 wall mounting is not recommended The switch must be wall mounted with the Ethernet ports facing either the floor or the ceiling ...
Page 8: ...ber cables SFP adapters sold separately Step 3 Connect RESET 1 3 5 7 2 4 6 8 Link Act 1 Gbps 9 SFP 10 SFP Link Act 1 Gbps RESET 1 3 5 7 2 4 6 8 Link Act 1 Gbps 9 SFP 10 SFP Link Act 1 Gbps Computer Switch Switch 120V AC Wall Outlet Router ENABLED IP Camera NOTE AN 310 SW R 8 POE shown Connection is the same for models with both front and rear facing ports ...
Page 9: ...imits the total number of watts available between all of the ports limited to 30W total consumption on each port Add the total number of watts consumed by all connected PoE devices to ensure that every thing can be powered as illustrated in the example below Total PoE Device Consumption 42W PoE Budget Left Available 88W Total PoE Budget Available 130W 8W 8W 12W 14W Model PoE Budget AN 310 SW F R 8...
Page 10: ...2 1Gbps LED On port connected at 1000Mbps speed Off port is connected at 10 100Mbps speed 3 Link Act LED On port is connected to another device Blinking packets are running through the port Off port is not connected to a device A B C 1 Gbps Link Act AN 310 SW R 8 POE 1 2 3 4 5 6 7 8 9F 10F AN 310 SW F 8 POE AN 310 SW R 8 POE AN 310 SW F 8 POE ...
Page 11: ...s remote firmware upgrades real time notifications and intuitive customer management right from your computer or mobile device Setup is plug and play with no port forwarding or DDNS address required To add this device to your OvrC account Connect the switch to the network Internet access required Log Into OvrC www ovrc com or load the OvrC app Add the device MAC address and Service Tag numbers nee...
Page 12: ...o Web Interface In the OvrC interface find the IP address of the switch in the customer device list Open a web browser and enter the IP address to navigate to the switch interface must be on the same LAN Log in to the interface using the default credentials A B C Username araknis Password araknis ...
Page 13: ...nnected to the network the DHCP server is usually in the network router If you haven t connected the switch to your OvrC account yet use one of these methods to find its IP address Check the client table on your router Use a network scanner e g Fing to sniff the network The switch manufacturer field will display Araknis See the highlighted field in the Fing screenshot to the right for an example o...
Page 14: ...ected to a network you can configure your computer s network connection to allow access using the default IP address 192 168 20 254 Connect your PC to the switch using a network patch cable On your PC open the Control Panel and left click Network and Internet Left click Network and Sharing Center Windows 7 screenshots shown for reference Computer Switch 1 Gbps Link Act AN 310 SW R 8 POE 1 2 3 4 5 ...
Page 15: ...r Access Methods Default IP Address Cont d D E F In the left bar left click Change adapter settings Right click the icon for the wired network connection and left click Properties Left click to highlight Internet Protocol Version 4 TCP IPv4 then left click Properties Windows 7 screenshots shown for reference ...
Page 16: ... then left click OK to close wireless network connection properties In the General tab left click Use the following IP address and enter the IP address and subnet mask IP Address 192 168 20 2 Subnet Mask 255 255 255 0 Open a web browser and navigate to the address h t t p 1 92 1 6 8 2 0 2 5 4 Log in using the default credentials Username araknis Password araknis Windows 7 screenshots shown for ref...
Page 17: ...e The switch will power cycle and the front status lights will flash Factory Reset Press and hold the RESET button for 10 15 seconds until the status LEDs flash once The switch will power cycle and be reset to factory default settings Pro Tip Resetting the Switch RESET 1 3 5 7 2 4 6 8 Link Act 1 Gbps 9 SFP 10 SFP Link Act 1 Gbps Front Facing Models Rear Facing Models 48 Port Models 1 Gbps PoE ...
Page 18: ......
Page 19: ......
Page 20: ...nder normal conditions of use This warranty shall not apply to products that have been abused modified or disassembled Products to be repaired under this warranty must be returned to a designated service center with prior notification and an assigned return authorization RA number Contact technical support for an RA number Contact Information araknisnetworks com Technical Support 866 838 5052 tech...