7
5.3
Attachment
The MP400 series pumps are equipped with an attachment with a drilled plate that allows the positioning also in very narrow areas or where there is
just the space for the pump.
Use M8 screws and bolts for the fixing.
IMPORTANT:
IN ORDER TO INSTALL THE PUMP CORRECTLY, OBSERVE THE FOLLOWING PRECAUTIONS:
1) The inlets/outlets must be placed in fixed positions.
2) Before drilling and fixing the plate, check the actual space according to the different types of motors or pulleys.
3) Take into account the spaces needed for the correct positioning of the hydraulic pipes, where provided, or the power cables.
4) Choose a well ventilated point for the positioning, as the pump will become hot while in operation.
47.5
80
120
175
X1
60
111
Motor
X1
(mm)
7,2
cm³/rev.
116
11,2
cm³/rev.
121
14,5
cm³/rev.
5.4
Pump assembly direction
The MP400 pump can be fitted in different positions,
but the outlet must never be pointed downwards (Fig.
5).
OK
OK
OK
NO!
Fig. 4
Tab. 4