SELETRON CONNECTION
13
SELETRON CONNECTION
PLEASE CAREFULLY FOLLOW THE INSTRUCTIONS PROVIDED IN THIS CHAPTER. ANY MISTAKE
DURING SELETRON PAIRING/REPLACEMENT MAY LEAD TO SYSTEM OPERATION FAILURE.
Seletron does not respond.
Power supply error on Seletron devices: power voltage lower than the allowed value.
Correct operation.
Fig. 107
BEFORE PROCEEDING, MAKE SURE YOU ARE ABLE TO HEAR THE ACOUSTIC
SIGNALS COMING FROM THE MONITOR LOCATED IN THE CABIN (DOORS OPEN,
ETC.).
• Access the menu (par. 12.7.6)
Data and settings > System status > Seletron status
• Make sure that ALL SELETRON DEVICES ARE DISCONNECTED: they must be shown on
the display only with the symbols
, as shown in Fig. 107.
Seletron 1
Seletron 1
Seletron 2, 3, etc.
Seletron 2, 3, etc.
seconds
Fig. 108
BEFORE CONNECTING A NEW SELETRON, MAKE SURE THAT THE PREVIOUS ONE HAS
BEEN PAIRED
,
that the acoustic signal has been made and that the relevant green symbol has been
displayed.
In case of errors during the pairing procedure, (the display shows the symbol
) reset all identification numbers and repeat
the procedure from the start (
ID Reset,
, par.
13.1).
• Connect the first Seletron.
Seletron no. 1 is the first on the left, when looking at the boom from behind (
Fig. 108).
WAIT FOR THE ACOUSTIC SIGNAL BY THE MONITOR. WAIT FOR THE MONITOR TO DISPLAY THE GREEN
SYMBOL FOR THE CONNECTED SELETRON
(
).
•
ONLY NOW
is it possible to proceed with the installation of the following Seletron
.
WARNING: ALL SELETRON DEVICES MUST BE INSTALLED IN A SEQUENCE FROM LEFT TO RIGHT (when
looking at the boom from behind).
•
Repeat the above steps, connecting all remaining Seletron devices from left to right until the end of the boom.
• Connection sequence in presence of end nozzles (par. 16.1):
“BUFFER ZONE” NOZZLES
start by connecting the “Buffer zone” Seletron, which is located on boom
left end, then connect all the “standard” Seletrons in their correct order from
left to right and, at last, connect the “Buffer Zone” Seletron located on boom
right end.
“FENCE" NOZZLES
start by connecting all "standard" Seletrons in their correct order
from left to right, then connect the "Fence" Seletron located on boom
left end and, at last, connect the "Fence" Seletron located on boom
right end.
"Buffer zone"
"Buffer zone"
RIGHT
RIGHT
"Buffer zone"
"Buffer zone"
LEFT
LEFT
"Fence" nozzles
"Fence" nozzles
CONTINUES > > >