24
IMPLEMENT SETTINGS
11.5
Home > data and settings > implement settings > Nozzle data
It allows setting the characteristic data of 12 ISO and 6 “User” (A ÷ F) nozzle types.
1
5
3
6
4
2
2
Fig. 46
2
Fig. 47
1 - 2
Select the nozzle to be set (Fig. 46
Fig. 47); enter the characteristics (Fig. 46).
If necessary, repeat the setup for each nozzle.
3 - 4
Set the reference flowrate and pressure for the selected nozzle.
The flowrate of the nozzle being used allows IBX100 to calculate the pressure without a pressure sensor.
The values for
Flowrate
and
Pressure
can be modified for “User” nozzles ONLY, not for ISO nozzles.
5 - 6
Set the pressure limits for the selected nozzle.
Enable the proper function in the menu
Info and alarms
(
12.3) if you want the computer to trigger an alarm when the nozzle is outside the set range.
For the procedure to be followed when an alarm occurs, please refer to
par.
17.3.
When using an implement with or twin or fourfold Seletron technology or a sprayer with dual boom valve technology, it is possible to customize the
selection of the pressure at which to change nozzle or nozzle combination based on the pressure values for the selected nozzles.
When setting a spraying, make sure to couple compatible nozzles.
For example:
In the same way, the overall rate of both nozzles at MINIMUM pressure shall be LOWER than the rate of the high rate nozzle at MAXIMUM pressure.
E.g.
The
Sprayer capability > Nozzles configuration
menu allows verifying that the settings for the selected nozzle have been made correctly
.
If there are errors in the configuration the device shows this symbol
.
Quits without confirming the
changes
Saves the changes
Cancel
Exits
Confirm
Goes back to previous menu,
or scrolls the pages of a menu
(previous page)
Scrolls the pages of a menu
(next page)
Goes back to main screen
Saves the changes to current
page
Summary of Contents for 4679004
Page 75: ...Notes 75...