VP5000-DC/DC60, VP5000-DC/DC200-HL
Product description
Last edited 2019-02-08
by Sonja Scheunert
Filename
VP5000_DCDC60_200-HL_installation_manual_v1-4en.docx
30 / 173
[ST1]: Analog voltage input
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
Measuring range
±10 V
Impedance
50 k
Ω
Accuracy
2.5%
Table 9: Electrical data - [ST1]: analog voltage input
[ST1]: Analog current input
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
Measuring range
±20 mA
Impedance
50
Ω
Accuracy
2.5%
Table 10: Electrical data - [ST1]: analog current input
[ST1]: Digital input
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
Maximum input voltage
28 V
Input impedance
20 k
Ω
Table 11: Electrical data - [ST1]: digital input
[ST1]: Digital output 1 and 2
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
Maximum output voltage
24 V (depending on the supply voltage for the logical connections)
Maximum current
(connected to ground)
0.2 A
Impedance (connected to
ground)
4
Ω
Table 12: Electrical data - digital output 1 and 2 to [ST1]