2.5 External air supply connections
Page 10
BK 746 Specific
LAGOM Stove User Guide
2.6 Rear flue spigot connection
The default factory setting for the Lagom, is for the rear air supply connection blanked
closed.
The air for combustion enters the firebox from the air connection spigot mounted on the
base of the appliance. The diameter of this connection is smaller than the flue connections
at 125mm.
Both these terminals are interchangeable and can be swapped to suit installation
requirements.
If an external air connection is required for installation, then a suitable supply duct of
125mm diameter in metal construction is recommended.
External Air Connection—Rear
Default External Air Connection— Base
(Showing Connection Spigot)
Rear
Connection
Blanked Closed
The default factory fitment for the Lagom, is for the flue spigot (150mm diameter) to be
fitted to the top outlet.
Provision for a rear fitted flue can be accessed via the knock-out cover in the rear panel of
the appliance (see above picture). Once removed, access to the rear flue will be visible.
Both these top and rear terminals are interchangeable and can be swapped to suit
installation requirement.
Rear
Knock Out
Cover For
Rear Flue
Connection