TECHNICAL DATA UK & EU Only 

TECHNICAL DATA 

Farringdon       

Catalyst Eco 

Maximum / Nominal Heat Output Kw  

11.4 

Mean Flue Gas Temperature °C 

279 

Height mm/inch 

659/26 

Width mm/inch 

533/21 

Depth mm/inch  ( handle removed ) 

330/13 

Flue Diameter mm/inch 

152/6 

Weight Packed Kg/lbs 

185/408 

Weight Nett Kg/lbs 

172/379 

Maximum Log Length inch (mm) 

12/300 

Maximum Log Diameter inch (mm) 

4/102 

Fuel 

Beech Wood 

Efficiency Nett (%) 

82.4 

Mean Co Emission @ 13% O2 (%) 

0.12 

Flue Mass Gas Flow (g/s) 

7.5 

Typical Fuel Load To Achieve Nominal 

Rated Output Per Hour (Kwh/Kg) 

2.39 

Mean CH Emission @ 13% O2 (%) 

91 

Mean NOx Emission @ 13% O2 (%) 

92 

DIN Plus Particulates @ 13% O2 (%) 

24 

Arada Farringdon Stoves 

Summary of Contents for Farringdon Catalyst Eco

Page 1: ...ISSUE DATE 10 06 2018 PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK724 SPECIFIC Rev 08 Farringdon Catalyst Eco ADDITIONAL INFORMATION FOR UK EU only EN13240 2011 A2 2004...

Page 2: ...632052 or visit our website www aradastoves com which offers a wealth of information on how to care for and get the best from your stove Please ensure that you read these instructions in full and unde...

Page 3: ...etroleum coke or Bituminous house coal must NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Please ensure that the air inlet vent grills to the dwelling...

Page 4: ...x 20 Set Screw NOTE Applicable To UK EU INSTALLATION ONLY To comply with the European standards EN 13240 2011 A2 2004 the 2 No M6x20 set screws must be fully inserted into the threaded holes in the po...

Page 5: ...ottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 Similarly in Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture Environment...

Page 6: ...Smoke Control exemption Always recharge onto hot embers After re charging fully open both the primary and secondary air controls for the following times in order to establish good combustion Farringd...

Page 7: ...ill be active when the thermometer indicates 300 C or above the bypass door should then be closed The stove should be run with sufficient combustion air to maintain a temperature above this level to e...

Page 8: ...guarantee only Catalyst element CAT FAR1601 has a limited 5 year warranty against thermal degradation and disintegration This guarantee is subject to the Terms and Conditions set out below Terms and...

Page 9: ...e guarantee is only valid if the stove is serviced and checked annually by a suitably qualified heating engineer with documentation to be retained and produced in the event of a claim being made 11 Th...

Page 10: ...ue Diameter mm inch 152 6 Weight Packed Kg lbs 185 408 Weight Nett Kg lbs 172 379 Maximum Log Length inch mm 12 300 Maximum Log Diameter inch mm 4 102 Fuel Beech Wood Efficiency Nett 82 4 Mean Co Emis...

Page 11: ...t Air Adaptor AFS4466 xxxx 10 Hinge Catch Plate AFS3865 33 Heatshield Insulation AFS4467 11 Ash Pan AFS4454 34 Heatshield AFS4468 12 Control Knob AFS3860 35 Catalyst Door AFS4469 13 Air Slider Assembl...

Page 12: ...ue Date 10 06 2018 Page 12 All Arada Stoves are manufactured in the UK Arada Ltd The Fireworks Weycroft Avenue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050 Email info...

Reviews: