background image

BK595 

EN 13240:2001+ 

Amd. A2 

September 2013

 

         

   

  

 

PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE

 

Boiler User Guide 

For stove ranges: 

Villager Boilers 

 

Summary of Contents for BK595

Page 1: ...BK595 EN 13240 2001 Amd A2 September 2013 PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE Boiler User Guide For stove ranges Villager Boilers...

Page 2: ...e for use on closed appliances including multi fuel stoves If in doubt contact The Solid Fuel Association telephone 0845 601 4406 01773 835400 or visit www solidfuel co uk It is a legal requirement th...

Page 3: ...chimney your wood is green or too wet PAPER Paper will burn successfully Burn dry paper only or chimney damage will occur WARNING NEVER BURN PLASTICS HOUSEHOLD WASTE OR LIQUID FUELS IN YOUR STOVE SOLI...

Page 4: ...itial lighting of the stove Please ensure your hearth is protected from the possibility of being permeated discoloured by condensation AIR INLET CONTROLS Your stove has three air inlet controls These...

Page 5: ...position Light the fire After the kindling has caught light you should leave the fire door ajar by about 20mm This will aid flue draw The flue draw should be established after five minutes and the kin...

Page 6: ...ed and corrected MULTI FUEL GRATE The grate in your stove comprises of a series of reciprocating cast iron bars seated on a pivoted comb These should come pre assembled in your new stove All bars in t...

Page 7: ...d deposits in the chimney This effect can be minimised by burning hard for a short period fifteen to twenty minutes twice a day The additional air inlets can be used to achieve this faster burn rate R...

Page 8: ...sting The fire door can be re aligned as follows When the appliance is cold open the fire door so that it is at right angles to the front of the stove Lift the fire door up off its hinges Gently tap t...

Page 9: ...rial and door glass are therefore not covered by the guarantee The external paint finish and thermostat carry a one year guarantee only The guarantee is conditional upon the appliance being installed...

Page 10: ...26 8 6 Technical Information Description Height mm inches Freestanding Output to Room kW Output to Water Solid Wood kW kW Product Code 1 kW 3 420 BTU Boiler Tapping Positions Villager Boiler 12kW Duo...

Page 11: ...490 19 3 521 20 5 154 6 200 150 152 6 70 5 Depth mm inches Width mm inches Depth from back to centre of top flue mm inches Height to centre of rear flue mm inches Flue Diameter mm inches Nett Efficien...

Page 12: ...ate Door Catch Door Handle Operating Tool Stove Glove Grate Fuel Bed Installation Guide Assembled by Checked by Model The Fireworks Weycroft Avenue Axminster Devon EX13 5HU www aradastoves com www ara...