INSTALLATION 

opening and clean off any surplus fire cement. 

Note: 

The flue pipe must be fitted inside the 

outlet spigot. Failure to do so could result in 
the spillage of condensation running down the 
flue.  

 

SEALING THE BACK AND BASE OF  
INSET STOVES TO A FIRE  
SURROUND

 

In order for the stove to operate correctly and 
at maximum efficiency it is necessary to 
achieve a good seal between the back face 
of the stove convector section, the stove back 
base sections and the decorative fire surround 
and hearth. 

This should be achieved using fire cement.  
Any void surrounding an inset stove when  
installed should be filled with fire cement in the 
interest of safety and efficiency. 

 

ADJUSTING THE SELF 
LEVELLING FEET (IF APPLICABLE)

 

Adjustment is as follows: 

 

Position the stove on the hearth into its 
final resting place.

 

 

On the rear leg of the stove, loosen the 
pozi screw, and rotate the inner ‘cam’ 
shaped levelling foot until this touches 
the hearth.  

 

Re-tighten the pozi screw. Check the 
stove is level with a spirit level. 

 

Repeat for the other rear leg.

 

 

 

FIRE BED SURROUNDS 

 

 

 

Cast fire bed surrounds are supplied with the  
boiler stove and should be fitted into the  
retaining holes in the rear grate bar support. 

 

GRATE BARS 

The grate comprises of a series of cast iron grate 
bars, seated on a pair of combs. All bars in the 
grate are identical.  

The bars should be seated with every other bar  
rotated 180 degrees, so the ends marked ’H’ and 
’L’ alternate on each comb. The ends marked ‘L’ 
should be seated on the low part of the comb, 
whilst the ends marked ‘H’ should be seated on 
the high sections. 

 

 

 

 

 

 

Flue Exhaust Diversion System 
(FEDS) 

(Not applicable to EB25HE)

 

The inner section of the FEDS is welded in place 
during manufacture. The outer FEDS is fitted at 
the factory but may become dislodged during 
transit. The rear end of the outer FEDS sits on  

Summary of Contents for BK555

Page 1: ...Wet Stove Installation Guide BK555 Rev03 EN 13240 2001 October 2013...

Page 2: ...ibuting plate should be taken to achieve it Ideally the appliance should stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Pl...

Page 3: ...TION All stoves require ventilation to burn safely and correctly There are requirements that need to be met when installing a stove such as allowing for the permeability of the house air permeability...

Page 4: ...resting place On the rear leg of the stove loosen the pozi screw and rotate the inner cam shaped levelling foot until this touches the hearth Re tighten the pozi screw Check the stove is level with a...

Page 5: ...similar problems A chimney terminating above the ridge level is generally less likely to suffer such problems If a new chimney is being built installed it should fully comply with the relevant Buildin...

Page 6: ...boss 1 BSP parallel Remember to incorporate a drainage plug Arada Installation Manual 6 INSTALLATION tap at the lowest point of the circuit to facilitate draining and flushing If a pipe stat is not f...

Page 7: ...to the boiler and steam vented from it at all times The use of an expansion tank is important This should have a capacity of at least 7 of the systems total water capacity The cold water feed pipe sh...

Page 8: ...m body on a small piece of 8mm thick MDF or similar wood Arada Installation Manual 8 INSTALLATION Now measure the high end of the damper plate between the bench and the top edge of the damper the edge...

Page 9: ...age 7 Carefully clean away any cold ash from the thermostat mechanism and housing cavity using a vacuum cleaner Refit the access cover To remove ash from the inner left landing cavity Make sure the st...

Page 10: ...to prevent any stains becoming burnt on Check the flue draught which should read 1 2mm or 0 1 0 2 mbar For a registered competent persons scheme such as HETAS please complete a Certificate of Complia...

Page 11: ...INSTALLATION 11 Arada Installation Manual...

Page 12: ...INSTALLATION Arada Installation Manual 12...

Page 13: ...INSTALLATION 13 Arada Installation Manual...

Page 14: ...Arada Installation Manual 14 INSTALLATION EXAMPLES Central heating and domestic hot water system using four boiler tapings Central heating without domestic hot water system using four boiler tapings...

Page 15: ...15 Arada Installation Manual INSTALLATION EXAMPLES Central heating and domestic hot water system using three boiler tapings Central heating without domestic hot water system using three boiler tapings...

Page 16: ...tice Due to printing cycles items or options may be described before they are generally available or after they have ceased so please check with your retailer or dealer Wet Stove Installation Guide BK...

Reviews: