Wet Stove Installation Guide
BK555 Rev03
EN 13240:2001+
October 2013
Page 1: ...Wet Stove Installation Guide BK555 Rev03 EN 13240 2001 October 2013...
Page 2: ...ibuting plate should be taken to achieve it Ideally the appliance should stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Pl...
Page 3: ...TION All stoves require ventilation to burn safely and correctly There are requirements that need to be met when installing a stove such as allowing for the permeability of the house air permeability...
Page 4: ...resting place On the rear leg of the stove loosen the pozi screw and rotate the inner cam shaped levelling foot until this touches the hearth Re tighten the pozi screw Check the stove is level with a...
Page 5: ...similar problems A chimney terminating above the ridge level is generally less likely to suffer such problems If a new chimney is being built installed it should fully comply with the relevant Buildin...
Page 6: ...boss 1 BSP parallel Remember to incorporate a drainage plug Arada Installation Manual 6 INSTALLATION tap at the lowest point of the circuit to facilitate draining and flushing If a pipe stat is not f...
Page 7: ...to the boiler and steam vented from it at all times The use of an expansion tank is important This should have a capacity of at least 7 of the systems total water capacity The cold water feed pipe sh...
Page 8: ...m body on a small piece of 8mm thick MDF or similar wood Arada Installation Manual 8 INSTALLATION Now measure the high end of the damper plate between the bench and the top edge of the damper the edge...
Page 9: ...age 7 Carefully clean away any cold ash from the thermostat mechanism and housing cavity using a vacuum cleaner Refit the access cover To remove ash from the inner left landing cavity Make sure the st...
Page 10: ...to prevent any stains becoming burnt on Check the flue draught which should read 1 2mm or 0 1 0 2 mbar For a registered competent persons scheme such as HETAS please complete a Certificate of Complia...
Page 11: ...INSTALLATION 11 Arada Installation Manual...
Page 12: ...INSTALLATION Arada Installation Manual 12...
Page 13: ...INSTALLATION 13 Arada Installation Manual...
Page 14: ...Arada Installation Manual 14 INSTALLATION EXAMPLES Central heating and domestic hot water system using four boiler tapings Central heating without domestic hot water system using four boiler tapings...
Page 15: ...15 Arada Installation Manual INSTALLATION EXAMPLES Central heating and domestic hot water system using three boiler tapings Central heating without domestic hot water system using three boiler tapings...
Page 16: ...tice Due to printing cycles items or options may be described before they are generally available or after they have ceased so please check with your retailer or dealer Wet Stove Installation Guide BK...