Aarrow Stove User Guide
below. This will ensure a good under draught is maintained. This should
be done with the supplied operating tool whilst wearing protective gloves.
5.5
Warning - Fume / Smoke emissions
Warning: Properly installed, with a suitable flue or chimney,
operated and maintained correctly, this appliance will not
emit fumes into the dwelling.
Occasional fumes when de-ashing and refuelling may occur.
However, persistent fume emission is potentially dangerous
and must be investigated by a HETAS registered installer.
Stop using the appliance if you smell fumes or see
smoke escaping.
If fume emission does persist, the following immediate
actions should be taken:
• Open doors and windows to ventilate room.
• Let the fire die or extinguish and safely dispose of fuel
from the appliance.
• Check for flue or chimney blockage, and clean if
required.
Seek expert advice from your HETAS registered installer. Do
not attempt to re-light the fire until the cause of the fume
emission has been identified and corrected.
5.5.1
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel
charge, excessive smoke emission can occur. Refuelling must be carried
out onto a sufficient quantity of glowing embers and ash that the new fuel
charge will ignite in a reasonable period. If there are too few embers in the
fire bed, add suitable kindling to prevent excessive smoke