ARA mini 6 User Manual Download Page 5

5

A/S Inquiry : +82-2-3452-8966 / [email protected]

USER MANUAL

MINI CENTRIFUGE

2. Product Description

The mini 6 table-top centrifuge runs up to 6,500 rpm with fast acceleration and 
deceleration, 4 seconds and 2 seconds respectively. It starts to spin when the lid is closed 
and stops when the lid is open. Simple action of “Lid Open Button” make its operation 
much easier. 

The magnet sensor between the lid and the body recognizes the status of lid and keeps 
its safe operation.

1-2.Precautions for Use

1. Place the body on a flat, rigid surface.

2. Keep the body dry and clean.

3. When adding samples to the rotor, adjust the weight of the samples

and place them symmetrically.

4. Do not move the equipment while it is spinning.

5. Do not arbitrarily decelerate or stop the rotating rotor.

6. Do not spill liquid or put foreign substances into the body or power adaptor.

If liquid is spilt inside the equipment or around the power connection, disconnect the
power adaptor and clean and dry all parts completely. If it is not working even with
full cleaning, contact A/S center.

7. Stop running if the equipment makes big noise or trembling. Check the rotor coupling 

and sample balance. If the problem is not eliminated, contact A/S center.

8. Do not apply a strong impact or move the equipment while it is spinning.

9. Precautions for handling power adaptors

- Do not pull or bend the power adaptor hard.
- Do not heat the cord or use it in humid places.
- Do not keep the power adaptor with power supplying status if it is not in use.

Summary of Contents for mini 6

Page 1: ...ARA mini 6...

Page 2: ...RESEARCH USE ONLY PRODUCT INFORMATION Model ARA mini 6 Manufacturer GYROZEN Co Ltd 1F 5F 16 Arayuk ro Gimpo si Gyeonggi do KOREA ARA mini 6 UM mini 6 Rev 3...

Page 3: ...e notice 1 Safety Precautions 4 1 1 Precautions for Installation 4 1 2 Precautions for Use 5 2 Product Description 5 3 Configuration 6 4 Product Specifications 7 5 Installation and Operation 8 5 1 Pow...

Page 4: ...cautions for Installation 1 Avoid hot humid places and install in well ventilated areas 2 Keep a distance of 30 cm from the wall and install it horizontally on a vibration free rigid table 3 For safet...

Page 5: ...hem symmetrically 4 Do not move the equipment while it is spinning 5 Do not arbitrarily decelerate or stop the rotating rotor 6 Do not spill liquid or put foreign substances into the body or power ada...

Page 6: ...de Selection Switch Operation change switch Lid As soon as the lid is closed the rotor starts to spin As soon as the lid is opened the rotor stops to spin Short mode S Spin for 12 sec while the lid is...

Page 7: ...e 2 234 xg 2 PCR Strips Rotor 1 412 xg Radius Angle Rotor 1 5 2 0 mL x 6 hole 47 3 mm 2 PCR Strips Rotor 29 9 mm Tube capacity 6 x 1 5 2 0 mL 2 x 8 tube PCR Strips Time Selectable Short 12 sec or Cont...

Page 8: ...It is for user s safety It will be properly functioned when the lid is simply open and closed 1 Check if the rotor and the lock nut are on place and tightly fixed to the motor shaft 2 Connect the DC a...

Page 9: ...5 2 Operation 1 Rotor coupling and decoupling This model is supplied with a coupled rotor In case of any needs of decoupling use the supplied spanner Counterclockwise turns make decoupling and clockw...

Page 10: ...2 Max RPM RCF 6 500 rpm 1 379 xg 6 500 rpm 1 710 xg 6 Trouble Shootings If the equipment does not operate 1 Incorrect connection between power adaptor and equipment Please check if the main body and t...

Page 11: ......

Page 12: ...im ara com...

Reviews: