Model 40S6G18-L
16
Rev E
2.4.6.11
Operating Hours (Power On)
Query to get the Power On operating hours.
Syntax:
OHP?
Parameters:
None
Response Format:
OHP=x<LF>
Where:
x
=
0
to
100000
Units are Hours. Values can be up to six digits in length. Leading zeros are read as
spaces.
Example:
To find out the Power On operating hours, send the following query:
OHP?<LF>
Response:
OHP=<space><space><space>428<LF>
(The system has spent 428 Hours in a Power On state)
2.4.6.12
SBB (Piggyback) Firmware Revision
Query to get the firmware revision of the piggyback SBB assembly.
Syntax:
*SBB?
Parameters:
None
Query only (always requires a ? character)
Response Format:
SBB_SW_REVx<LF>
Where:
x
= firmware revision
Example:
To get the firmware rev. of the piggyback SBB assembly, send the following command:
*SBB?<LF>
Response:
SBB_SW_REV2.60<LF>
Summary of Contents for 20S6G18-L