Model 125W1000A
16
Rev A
2.7 FAULT DEFINITION
This section is used to define all faults that can occur and their source. Use the Control Line column to define
what active control line generates the fault or use the text
Internal
for an internally generated fault from the
control system (i.e ‘
Internal 485 bus error
’). See the Control Lines section for details about each control line
referenced. See the Control Lines section for details about each control line referenced. If there are more than
one Switch Break Out boards, add the interconnect designation to the A# column.
A check mark in the
RF Inhibit
column indicates the RF output of the driver stages will be attenuated. A check
mark in the
Drop to RF OFF
column indicates the control state will be changed to
Power ON, RF OFF
.
A#
Control
Line
Fault Details
RF
Inhibit?
= Yes
Drop to
RF OFF?
= Yes
Hex
Dec
Fault Text
(<15 Characters)
Description
00
0
No Fault
A7A3
J5-30
0x0001
1
Interlock
Interlock
Internal
0x0019
25
485 Error
RS-485 Comm Bus Error
Internal
0x001e
30
System Error C
Internal communication error
(Mounted SBB ASSY failure)
A7A3
J5-29
0x0020
32
PS1 DC
Pwr Supply Failure: PS1
A7A3
J5-28
0x0021
33
PS2 DC
Pwr Supply Failure: PS2
A7A3
J5-22
0x0022
34
PS2 Thermal
Pwr Supply Thermal Failure: PS2
A7A3
J5-9
0x0200
512
Amp A2
Amplifier Fault, Final A2#1 Module
A7A3
J5-10
0x0201
513
Amp A3
Amplifier Fault, Final A2#2Module
A7A3
J5-23
0x0400
1024
Thermal A2
Thermal Fault, Final A2 Module