AR 10044232 Operating And Service Manual Download Page 5

INSTRUCTIONS FOR SAFE OPERATION 

 

Revised 0517 

 

Observe the following safety guidelines to help ensure your own 

personal  safety and to help protect your equipment and working 

environment from potential damage. 

INTENDED USE 

This equipment is intended for general laboratory use in generating, 

controlling, and measuring levels of electromagnetic Radio Frequency 

(RF) energy. Ensure that the device is operated in a location which will 

control the radiated energy and will not cause injury or violate 

regulatory levels of electromagnetic interference. 

SAFETY SYMBOLS 

These symbols may appear in your user manual or on equipment. 

 

This  symbol is marked on the equipment when it is 

necessary for the user to refer to the manual for 

important safety information.  

The caution symbol denotes a potential hazard. 

Attention must be given to the statement to prevent 

damage, destruction, or harm. 

 

Dangerous voltages are present. Use extreme care.

 

 

 

Indicates a terminal intended for connection to an 

external conductor for protection against electrical 

shock in case of a fault, or the terminal of a protective 

earth (ground) electrode. 

 

Indicates invisible laser radiation–do not view directly 

with optical instruments. 

 

Indicates frame or chassis ground connection terminal. 

 

Indicates alternating current. 

 

Indicates this product must not be disposed of with your 

other household waste. 

 

Indicates that the marked surface and adjacent surfaces 

can attain temperatures that may be hot to the touch. 

 

EQUIPMENT SETUP PRECAUTIONS 

Review the user manual and become familiar with all 

safety markings and instructions.  Protection provided by 

the equipment may be impaired if used in a manner not 

specified by AR RF/Microwave Instrumentation (AR). 

 

Follow all lifting instructions specified in this document. 

 

Place the equipment on a hard, level surface. 

 

Do not use the equipment in a wet environment, for example, near 

a sink, or in a wet basement. 

 

Position your equipment so that the power switch is easily 

accessible.  

 

Leave 10.2 cm (4 in) minimum of clearance on all vented sides of 

the equipment to permit the airflow required for proper 

ventilation. Do not restrict airflow into the equipment by blocking 

any vents or air intakes. Restricting airflow can result in damage 

to the equipment, intermittent shut-downs or safety hazards. 

 

Keep equipment away from extremely hot or cold temperatures 

to ensure that it is used within the specified operating range.  

 

While installing accessories such as antennas, directional 

couplers  and field probes,  take care to avoid any exposure to 

hazardous RF levels.  

 

Ensure that nothing rests on your equipment’s cables and that the 

cables are not located where they can be stepped on or tripped 

over. 

 

Move equipment with care; ensure that all casters and/or cables 

are firmly connected to the system. Avoid sudden stops and 

uneven surfaces. 

BEFORE APPLYING POWER 

Your AR equipment may have more than one power supply cable. Use 

only approved power cable(s). If you have not been provided with a 

power cable for the equipment or for any AC-powered option intended 

for the equipment, purchase a power cable that is approved for use in 

your country. The power cable must be rated for the equipment and for 

the voltage and current marked on the equipment’s electrical ratings 

label.  

Incorrectly installing or using an incompatible line 

voltage may increase the risk of fire or other hazards. To 

help prevent electric shock, plug the equipment and 

peripheral power cables into properly grounded electrical 

outlets. These cables are equipped with three-prong plugs to help 

ensure proper grounding. Do not use adapter plugs or remove the 

grounding prong from a cable. 
Do not modify power cables or plugs. Consult a licensed electrician or 

AR trained service technician for equipment modifications. Always 

follow your local/national wiring rules.  

Do not operate the equipment if there is physical 

damage, missing hardware, or missing panels. 

 

SAFETY GROUND 

This equipment is provided with a protective earth 

terminal. The mains power source to the equipment must 

supply an uninterrupted safety ground of sufficient size to 

attach  wiring terminals, power cord, or supplied power 

cord set. 

DO NOT USE this equipment if this protection is impaired. 

 

 

Summary of Contents for 10044232

Page 1: ...Operating and Service Manual AA18G26 20 Model 10044232 Part Number Serial Number 160 School House Road Souderton PA 18964 215 723 8181 Fax 866 859 0582 www arworld us...

Page 2: ......

Page 3: ...EN 61010 1 Issued 2010 10 01 Ed 3 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Part 1 General Requirements UL 61010 1 Issued 2012 05 11 Ed 3 Safety Requirem...

Page 4: ......

Page 5: ...clearance on all vented sides of the equipment to permit the airflow required for proper ventilation Do not restrict airflow into the equipment by blocking any vents or air intakes Restricting airflow...

Page 6: ...a assembly may be heavy requiring two persons to lift Use caution when installing or removing unit Follow all equipment setup and lifting instructions specified in this document Ensure connectors are...

Page 7: ...von 10 2 cm 4 in auf allen bel fteten Seiten des Ger ts ein um eine ausreichende Luftzirkulation zu gew hrleisten Beintr chtigen Sie den Luftstrom des Ger ts nicht indem Sie L ftungs ffnungen oder de...

Page 8: ...allen in diesem Dokument angegebenen Anweisungen zur Anbringung Stellen Sie sicher dass alle Anschl sse f r den beabsichtigten Betrieb geeignet sind Informationen zu den Anschl ssen erhalten Sie im Be...

Page 9: ...tilation Ne limitez pas le flux d air allant dans l quipement en bloquant tout vent ou entr e d air La restriction du flux d air peut endommager l quipement causer des coupures intermittentes ou des d...

Page 10: ...dent lorsque vous installez ou retirez l unit Respectez toutes les instructions concernant l installation et le levage de l quipement indiqu es dans ce document Assurez vous que les connecteurs sont a...

Page 11: ...is voor goede ventilatie mogelijk te maken Belemmer de luchtstroom in het apparaat niet door ventilatieopeningen of luchtinlaten te blokkeren Het belemmeren van de luchtstroom kan leiden tot schade a...

Page 12: ...nstellen en optillen van de apparatuur die in dit document worden vermeld Zorg ervoor dat de connectoren geschikt zijn voor de beoogde werking De connectoren worden gespecificeerd in de gebruikershand...

Page 13: ...1 1 General Description 1 1 2 Specifications 1 1 3 Performance Data 1 1 4 Installation 1 1 4 1 Auxiliary Equipment Selection 1 1 4 2 General Caution Notes 2 2 OPERATING INSTRUCTIONS 5 2 1 General 5 2...

Page 14: ...Model AA18G26 ii...

Page 15: ...r temperature through forced air cooling 1 2 SPECIFICATIONS Refer to the AR data sheet at the end of this section for detailed specifications for the Model AA18G26 1 3 PERFORMANCE DATA Electric field...

Page 16: ...are thoroughly familiar with the hazards inherent to this type of equipment CAUTION The Model AA18G26 emits highly concentrated microwave fields Users should therefore take proper precautions when att...

Page 17: ...V m or 50 V m at 1 meter antenna distance MAXIMUM AMPLIFIER INPUT 10 dBm max FREQUENCY RESPONSE 18 26 5 GHz instan taneous 3dB BEAMWIDTH AA18G26 20 E Plane 17 5 degrees H Plane 17 8 degrees AA18G26 50...

Page 18: ...all 215 723 8181 For an applications engineer call 800 933 8181 Direct to Service call 215 723 0275 or email service arworld us For Faxing Orders 866 859 0582 Orders Only Please info arworld us Approv...

Page 19: ...tion adjustments The AA18G26 will only operate from 18 GHz to 26 5 GHz Do not use frequencies outside of this range 2 2 REQUIRED DC POWER The required DC power for the AA18G26 is 8VDC 6 amps max for a...

Page 20: ...Model AA18G26 6 Rev A...

Page 21: ...Rev A 7 3 AA18G26 OUTLINE 3 1 AA18G26 ASSEMBLY Refer to drawing 10044232 and 10044337 for the assembly drawings of the AA18G26 20 and AA18G26 50 respectively...

Page 22: ...8 Rev A...

Page 23: ...Model AA18G26 Rev A 9...

Page 24: ...10 Rev A...

Page 25: ...cover If the security label is removed and or cut the warranty of the module will be voided Vacuum tubes in the L series amplifiers traveling wave tubes in TWT amplifiers and power heads will be free...

Page 26: ......