![AR 10027190 Operating And Service Manual Download Page 31](http://html1.mh-extra.com/html/ar/10027190/10027190_operating-and-service-manual_2962273031.webp)
Models 200T18G26z5A/200T26z5G40A
Rev –
21
Table 3-6. Catalog of System State Codes
(The
RDLOGIC
command causes the TWTA to send a string containing an operational state code consisting
of 4 ASCII characters representing hex digits. The response is in the form
Sys:[w][x][y][z][eol]
where the
hex values of
[w],[x],[y] and [z]
are formed as shown below)
z bit
Meaning
0 (LSB)
High voltage on
1
Transmit on
2
Remote mode
3 (MSB)
Fault
y bit
Meaning
4 (LSB)
Heater time delay expired
5
Under forward power warning
6
Foldback active
7 (MSB)
Inhibit mode
x bit
Meaning
8 (LSB)
External inhibit
9
Interlock open
10
(not used)
11 (MSB)
(not used)
w bit
Meaning
12 (LSB)
(not used)
13
Sleep Mode Active
14
(not used)
15 (MSB)
(not used)
Table 3-7. *STA?; Response Codes
(The command
*STA?;
causes the TWTA to send a string indicative of the current system state)
*STA?; response
Meaning
SLEEP
Sleep Mode active (heater off)
WARM-UP
System is in heater time delay.
STANDBY
System is ready to allow high voltage on
OPERATE
High voltage is on and beam is on
FAULT
High voltage is off and system requires reset
Summary of Contents for 10027190
Page 2: ......
Page 4: ......
Page 8: ......