![AR 10012514 Operating And Service Manual Download Page 47](http://html1.mh-extra.com/html/ar/10012514/10012514_operating-and-service-manual_2962271047.webp)
4. MAINTENANCE
The TWTA does not require routine scheduled maintenance
.
The only moving parts are the elements of
switches, relays and blowers. Preventive maintenance is recommended in Paragraph 4.3.
The TWTA is basically a factory repairable unit
.
However
,
since limited logic schematics and partial parts
information is supplied in this manual (Section V) some user service organizations may choose to perform
their own corrective maintenance
. Warnings and Cautions should be observed.
4.1 SAFETY
WARNING
WARNING:
Service work must be performed only by technicians thoroughly familiar
with the high voltages present in microwave tube amplifiers in general,
and with this equipment in particular.
Never handle the TWT leads or the high-voltage connectors unless it has
been positively established that the high-voltage filter capacitors have
been discharged to a known safe level.
CAUTION:
A malfunctioning power supply can cause damage to the TWT. If you are
troubleshooting the TWTA, remove the TWT and substitute suitable
loads to prevent damage to the TWT.
4.2 UNAUTHORIZED
REPAIRS
CAUTION:
Unauthorized repairs or modification of this product during the warranty
period may void the warranty. In the event that the TWTA malfunctions
while it is still under warranty, always contact an authorized service
representative.
4.3 PREVENTIVE
MAINTENANCE
The RF characteristics and power supply voltages and currents of the TWTA should be logged on a regular
basis. Maintenance should be performed if significant deviations from the logged values appear. If the unit is
under warranty, contact an authorized service representative if impaired performance is suspected.
If there is accumulated dust on the air intake grill, clean it with dry compressed air.
If significant dust has been noted on the air intake grill, it may be desirable to vacuum the dust and debris
from inside the enclosure. To open the enclosure:
1.
Remove the amplifier from the cabinet or rack as follows:
NOTE:
Due to the weight of the unit, the removal of the amplifier from the cabinet or rack is a two-
person operation.
Rev A
29
Summary of Contents for 10012514
Page 2: ......
Page 4: ......
Page 14: ......
Page 16: ......
Page 24: ......
Page 46: ...Model 300T2G8 28 Rev A...
Page 50: ...Model 300T2G8 32 Rev A...
Page 54: ...Model 300T2G8 36 Rev A...
Page 55: ...5 3 WIRING DIAGRAMS 20 22520 000 TWT Power Supply 10 1 2 Series A22520 052 Rev A 37...
Page 56: ...Model 300T2G8 38 Rev A...
Page 72: ......