Model 200T8G18A/250T8G18
20
Rev D
Table 3-4. Catalog of Status Codes
(The RDSTAT command causes the TWTA to return a string in the form STATUS=[
code
], where [
code
] is
an ASCII number whose meaning is given below)
Status Code
Meaning
0
No command was given.
1
Last command was successful.
2
Last command is in process.
3
Last command failed to complete. Time-out.
10
Last command failed. Invalid command.
11
Last command failed. Data was unparseable.
20
Last set command failed. Data was beyond high limit.
21
Last set command failed. Data was beyond low limit.
22
Last set command failed. Data was out of range.
23
Last set command failed. Data was wrong polarity.
50
Last command failed. Local system does not have remote enabled.
51
Remote system is not ready to accept commands.
60
Command is not allowed in current system state.
901
Assert error: invalid table argument *
902
Assert error: invalid calibration *
* Please call a service representative if you observe this error.
Table 3-5. Catalog of Fault Codes
(The RDFLT command causes the TWTA to return a string in the form flt=[
code
], where [
code
] is an ASCII
number whose meaning is given below)
Fault Code
Meaning
0
No fault
7
System
Fault
8
Fil not ready
9
Low Line
10
Cathode
overvoltage
11
Body
overcurrent
12
Cathode
undervoltage
15
Collector
undervoltage
16
Inverter
fault
17
Internal interlock open
18
Tube arc
19
TWT
(hardware)
overtemperature
20
Cabinet (hardware) overtemperature
22
External
inhibit
23
Over reverse power
30
Grid or anode overvoltage
49
TWT
(software)
overtemperature
50
Cabinet (software) overtemperature
Summary of Contents for 10012510
Page 2: ......
Page 4: ......
Page 14: ......
Page 22: ......
Page 44: ...Model 200T8G18A 250T8G18 26 Rev D...
Page 48: ...Model 200T8G18A 250T8G18 30 Rev D...
Page 52: ...Model 200T8G18A 250T8G18 34 Rev D...
Page 54: ...Model 200T8G18A 250T8G18 36 Rev D...
Page 56: ...Model 200T8G18A 250T8G18 38 Rev D...
Page 70: ...Model 200T8G18A 250T8G18 52 Rev D...
Page 72: ......